Instrument Set-up Introduction Overview The safety instructions and the user manual should be read through carefully before the product is used for the first time. The person responsible for the product must ensure that all users understand these directions and adhere to them. Display The symbols used have the following meanings: WARNING...
Instrument Set-up Display Insert batteries To ensure a relia- Info ble use, do not use zinc-carbon batteries. Change batteries when battery Battery symbol is flashing. Area ® Bluetooth Units Main line Attach / Remove clip click! Leica DISTO E7100i 812795...
Operations Switching ON/OFF Clear Message Codes If the message "InFo" appears with a Press ON button number, observe the instructions in 2 sec to start "Message Codes" section. continuous laser Example: mode. 2 sec Device is turned Undo last action. Leave actual func- OFF.
Measuring Functions Measuring single distance Target surfaces: Measuring errors can occur when measuring to colourless liquids, glass, styrofoam or permaeble surfaces or when aiming at high gloss surfaces. Against dark surfaces the 8.532 measuring time increases. Aim active laser at target. Permanent measuring The last value measured is dis- played.
Measuring Functions Bluetooth Smart ® 2 sec Value from main- ® Deactivate/Activate Bluetooth I8.462 line is transferred ® App Mode: Use this mode to transfer the data using an App. Ready devices. All other Bluetooth devices do not support the energy ®...
Message Codes Care Warranty If the message Error does not disappear • Clean the device with a damp, soft cloth. Lifetime Manufacturer's Warranty after switching on the device repeatedly, • Never immerse the device in water. Warranty coverage for the entire usage time contact the dealer.
• Deliberate dazzling of third parties; also in Changes or modifications not expressly material, financial and environmental the dark approved by Leica Geosystems for compli- damage. • Inadequate safeguards at the surveying site ance could void the user’s authority to Important paragraphs which must be (e.g.
• Connect the equipment into an outlet on a of the original equipment: circuit different from that to which the WARNING Leica Geosystems AG receiver is connected. The device conforms to the most stringent Heinrich-Wild-Strasse requirements of the relevant standards and •...
Safety Instructions Use of the product with Blue- Laser classification Labelling tooth ® Laser Radiation WARNING Do not stare into the beam Electromagnetic radiation can cause distur- Laser class 2 bances in other equipment, in installations acc. IEC 60825-1:2007 Maximum radiant power: <1mW (e.g.
Page 13
Quality Management and Quality Systems (ISO standard 9001) and Environ- mental Management Systems (ISO standard 14001). Total Quality Management - Our commitment to total customer satisfaction. Ask your local Leica Geosystems agent for more information about our TQM program. Copyright Leica Geosystems AG, Heerbrugg,...