Inspecting the laser
plummet step-by-step
Check & Adjust
2
16550_001
The following table explains the most common settings.
1.
Place and secure the instrument into the tribrach and onto a tripod.
2.
Turn on the instrument. Connect the instrument to the field control-
ler. Using the tribrach footscrews, level the instrument with the
electronic level.
Electronic level:
Select Devices from the Home Menu.
Tap the arrow button to the right of the device name.
To display the electronic level, tap Compensator.
3.
The laser plummet is switched on when the Compensator screen is
displayed.
Inspection of the laser plummet should be carried out on
a bright, smooth and horizontal surface, such as a sheet
of paper.
Mark the centre of the red laser dot on the ground.
4.
Turn the instrument slowly through 360°, carefully observing the
movement of the red laser dot.
The maximum diameter of the circular movement
described by the centre of the laser dot should not
exceed 3mm at a height of 1.5m.
If the centre of the laser dot describes a perceptible circular move-
ment, or moves more than 3 mm away from the point which was
first marked, an adjustment may be required. Inform your nearest
Leica Geosystems authorised service centre. Depending on bright-
ness and surface, the diameter of the laser dot can vary. At 1.5 m, it
is about 2.5 mm.
3
4
360°
Ø 2.5 mm / 1.5 m
d 3 mm / 1.5 m