Repair
Cooling system
u Place guiding rods in place of two screws 3.
u Place thermostat housing.
u Place screws 3.
u Remove guiding rods.
u Place remaining screws.
u Screw thermostat housing 2 with screws 3, 6.
u Tighten screws to torque according to tightening specifications.
Information
Vent coolant circuit at the end of installation.
Specific values
Thermostats LT start to open at 45 °C (113 °F) and are fully opened at 57 °C (135 °F).
Tightening specifications
Refer to standard tightening torques.
page 264.)
3.10.5 Coolant pump HT removal and installation (SL 216)
Previous tasks
q Drain HT coolant circuit.
q Remove machinery HT cooling system piping.
Specific safety instructions
NOTICE
Risk of property damage by reuse of sealing.
Leakage by faulty seal.
u Replace all sealings.
Special tools
Special tool
Tab. 49: Special tools
220
(For more information see: 5.3 Standard tightening torques,
Guiding rod M12x100 - Coolant pump (x2)
© 2021 by Kohler Co. All rights reserved.
Service and Repair Manual
Designation
KD62V12 33525088601_7_1 EN_US