Set Up Instruction - netvox R718IB2 User Manual

Wireless 2-input 0-10v adc sampling interface
Hide thumbs Also See for R718IB2:
Table of Contents

Advertisement

4.Set Up Instruction

On/Off
Power on
Turn on
Turn off (Restore to factory setting) Press and hold the function key for 5 seconds till green indicator flashes 20 times
Power off
Note
Network Joining
Never join the network
Had joined the network
(Not restore to the factory setting)
Fail to Join the Network
Function Key
Press and hold for 5 seconds
Press once
Sleeping Mode
The device is on and in the
network
Low Voltage Warning
Low Voltage
Insert batteries (user may need a screwdriver to open)
Press and hold the function key for 3 seconds till the green indicator flashes once
Remove Batteries
1. Remove and insert the battery, and the device is in turn-off state by default
2. On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor
inductance and other energy storage components
3. In the first 5 seconds after power on, the device is in engineering test mode
Turn on the device to search the network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Turn on the device to search the previous network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Suggest to check the device verification information on the gateway or consult your platform
server provider.
Restore to factory setting / Turn off
The green indicator flashes 20 times: success
The green indicator remains off: fail
The device is in the network: green indicator flashes once and sends a report
The device is not in the network: green indicator remains off
Sleeping period: Min Interval
When the reportchange exceeds setting value or the state changes, the device send a data
report according to Min Interval.
3.2V
4

Advertisement

Table of Contents
loading