MEGA-PIXEL NETWORK CAMERA

Installation Instructions

CAUTION
• Cover Opening Alarm and External Alarm Input :
Cover Opening(Sabotage) Alarm and External Alarm Input are electrically tied
together internally.
Alarm contact types, N.O or N.C are selectable by the Alarm Input Selection
Jumper and the selection types should be matched with Alarm Type in setup
menu.
When both of Cover Opening Alarm and External Alarm Input are used at the
same time, the alarm contact types must match. Otherwise, alarm malfunctions.
When External Alarm Input only is used with disabling Cover Opening Alarm,
remove the jumper cap of Alarm Input Selection Jumper.
N.O : Alarm is generated when Junction box is OPEN.
N.C : Alarm is generated when Junction box is CLOSED.
Default setting for Alarm Input selection jumper is N.C. It prevents from Alarm is
generating when Junction box is OPEN during installation. Alarm Input selection
jumper should be set to N.O and Event Trigger/Action should be dened to enable
Cover opening alarm.
For Cover Opening Alarm, please go to SETUP> Event Rules> Event Processing>
Add Event Trigger should be set to "Alarm In" and then Event Action should be
set as available options.
[N.O]
Cover opening alarm switch
(Sabotage alarm)
Alarm Input selection jumper
09
[N.C]

Advertisement