Specifications - Para systems Minuteman PRO-RT 2U Series User Manual

Table of Contents

Advertisement

Chapter 8: Specifications
SYSTEM SPECIFICATIONS
Model Number
PRO750RT2U PRO1000RT2U
Topology
750VA
Maximum Power Capacity
525W
Number of Phase
Nominal Voltage
Acceptable Input voltage
Voltage Range
Frequency Limits
Low Voltage Transfer Point
89V resets to Utility Power at 94V or higher
High Voltage Transfer Point
151V resets to Utility Power at 146V or lower
Protection
Power Cord (10ft)
OUTPUT NON-BATTERY OPERATION
Voltage Range
Voltage Regulation
Frequency Range
Efficiency (Line Mode)
OUTPUT BATTERY OPERATION
Waveform Type
Nominal Voltage
Voltage Regulation
120VAC ±5% (until Low Battery Warning)
Frequency
60Hz, ±0.5Hz (unless synchronized to utility)
Transfer Time
AC Mode: 110% for 1-minute then shutdown, 150% Shutdown Immediately
Overload Capacity
DC Mode: 110% for 20-seconds then shutdown, 150% Shutdown Immediately
Protection
Over-Current, Short-Circuit Protected and Latching Shutdown
Receptacles (NEMA)
REGULATORY COMPLIANCE
Safety and Approvals
cTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-
14 / R: 2014), FCC Class B, CE certified, RoHS2 (EU Directive
2011/65/EU & 2015/863/EU)
28
PRO1500RT2U
PRO2000RT2U
Line-Interactive, Simulated Sine Wave
1500VA
2000VA
1000VA
700W
1050W
1400W
INPUT
Single (1∅ 2W +G)
120VAC
0 - 150VAC
90 - 150VAC
60 Hz, ±6Hz
Resettable Circuit Breaker
NEMA 5-15P
NEMA 5-20P
103 - 136VAC
120VAC: ±13.3%
60Hz: 54 - 66Hz
>96% (Full Load)
Simulated Sine Wave
120VAC
6-10 ms Typical
6: 5-15/20R
8: 5-15R
1: L5-20R
BATTERY SYSTEM
Battery Type
Sealed, Non-Spillable, Maintenance Free, Value Regulated Lead Acid
Typical Recharge Time
8-hours to 90% capacity from a full load discharge
Typical Battery Life
3 to 5 years. Environmental factors do affect battery life. High
temperatures, poor utility power, and frequent, short duration
discharges have a negative impact on battery life.
Battery Module Part #
BM0072
Runtime: Full Load (minutes)
5
Runtime: Half Load (minutes)
15
SURGE PROTECTION AND FILTERING
UPS Surge Energy Rating
Surge Current Capability
6500 Amps total (one time 8 to 20us waveform)
Response Time
0 ns (instantaneous) normal mode; <5 ns common mode
Surge voltage let-through (as a
percentage of an applied ANSI
C62.41 Cat. A ±2 kV)
Noise Filter
>45db normal and common mode EMI/RFI suppression
Audible Noise at 1 m (3 ft.)
Network/Phone/Fax/Modem
10/100/1000 Base-T network, single line phone, Fax or Mo-
transient voltage surge protection
dem. 1-in / 1-out combo RJ11/45 connectors
Coax transient voltage surge
Cable modem , CATV converter, DSS receiver, DVR.
protection
1-in / 1-out
ENVIRONMENTAL
Operating Temperature
Operating Elevation
Operating/Storage Humidity
Storage Temperature
Storage Elevation
PHYSICAL
Size - Net
16.1 X 18.9 X 3.4"
L X W X H
410 X 480.6 X 86.2 mm
31.3 lbs
Weight - Net
14.2 Kgs
Size - Shipping
22.4 X 21.7 X 9.4"
L X W X H
570 X 550 X 240 mm
37.5 lbs
Weight - Shipping
17.0 Kgs
BM0073
BM0074
BM0075
4
4
4
14
14
14
960 J
< 0.30%
<45 dBA
0 to 40°C (+32 to +104°F)
0 to 3000m (0 to +10,000 ft)
5- 95% Non-Condensing
-15 to +45°C (+5 to +113°F)
0 to 15,000m (0 to +50,000 ft)
20.1 X 18.9 X 3.4"
510 X 480.6 X 86.2 mm
48.7 lbs
35.7 lbs
62.8 lbs
16.2 Kgs
22.1 Kgs
28.5 Kgs
26.4 X 22.4 X 9.4"
670 X 570 X 240 mm
41.9 lbs
56.4 lbs
70.5 lbs
25.6 Kgs
19.0 Kgs
32.0 Kgs
29

Advertisement

Table of Contents
loading

Table of Contents