SYSTEM SPECIFICATIONS
Model Number
PRO500LCD
Topology
500VA
Maximum Power Capacity
350W
Number of Phase
Nominal Voltage
Acceptable Input voltage
Voltage Range
Frequency Limits
Low Voltage Transfer Point
90V resets to Utility Power at 94V or higher
High Voltage Transfer Point
150V resets to Utility Power at 146V or lower
Input Protection
OUTPUT NON-BATTERY OPERATION
Voltage Range
Voltage Regulation
Frequency Range
Efficiency (Line Mode)
OUTPUT BATTERY OPERATION
Waveform Type
Nominal Voltage
Voltage Regulation
Nominal +/-5% (until Low Battery Warning)
Frequency
50/60Hz, +/-0.5Hz (unless synchronized to utility)
Transfer Time
AC Mode: 110% for 5-seconds then fault, 120% Shutdown Immediately
Overload Capacity
DC Mode: 110% for 10-seconds then shutdown, 120% Shutdown Immediately
Protection
Over-Current, Short-Circuit Protected and Latching Shutdown
REGULATORY COMPLIANCE
Safety and Approvals
EMC Verification
20
PRO700LCD
PRO1100LCD
PRO1500LCD
Line-Interactive, Simulated Sine Wave
700VA
1100VA
1500VA
490W
770W
1050W
INPUT
Single (1 2W +G)
120VAC
0 - 160VAC
90 - 150VAC
50 or 60 Hz, +/-5Hz, autosensing
Resettable Circuit Breaker
104 - 132VAC
120VAC: -13.3% - +10.0%
60Hz: 55 - 65Hz or 50Hz: 45 - 55Hz
>90% (Full Load)
Simulated Sine Wave (Step Wave)
120VAC
6 ms Typical
cTUVus
(conforms to UL1778, CSA 22.2 standards)
FCC Class B, CE certified
BATTERY SYSTEM
Battery Type
Sealed, Non-Spillable, Maintenance Free, Value Regulated Lead Acid
Typical Recharge Time
From Full load dishcarge: 4-hours to 80%, 8-hours to 90%
Typical Battery Life
3 to 5 years. Environmental factors do affect battery life.
High temperatures, poor utility power, and frequent, short
duration discharges have a negative impact on battery life.
Battery Module Part #
BM0048
Runtime: Full Load (minutes)
5
Runtime: Half Load (minutes)
17
SURGE PROTECTION AND FILTERING
Surge Energy Rating
Surge Current Capability
10000 Amps total (one time 8 to 20us waveform)
Surge Response Time
0 ns (instantaneous) normal mode; <5 ns common mode
Surge voltage let-through (as a percentage
of an applied ANSI C62.41 Cat. A +/-6 kV)
10/100 Base-T surge protection let-through
(as a percentage of an applied +/-6 kV 1.2/50
us, 500 a 8/20 uS test)
Telephone line surge protection let-through
(as a percentage of an applied +/-6 kV 1.2/50
us, 500a 8/20 uS test)
Noise Filter
>45db normal and common mode EMI/RFI suppression
Audible Noise at 1 m (3 ft.)
ENVIRONMENTAL
Operating Temperature
0 to 40 degrees C (+32 to +104 degrees F) at
Operating Elevation
0 to 1,500m (0 to +5,000 ft)
Operating Temperature
0 to 35 degrees C (+32 to +95 degrees F) at
Operating Elevation
1501 to 3,000m (0 to +10,000 ft)
Storage Temperature
Operating/Storage Humidity
Storage Elevation
PHYSICAL
Size - Net
11.81 x 6.69 x 7.87"
L X W X H
300 x 170 x 200 mm
17.6 lbs
Weight - Net
8.0 Kgs
Size - Shipping
15.16 x 9.84 x 11.22"
L X W X H
385 x 250 x 285 mm
19.8 lbs
Weight - Shipping
9.0 Kgs
BM0051
BM0049
BM0050
7
7
5
21
21
17
760 J
< 11%
< 5%
< 1%
<45 dBA
-15 to +45 C (+5 to +113 F)
95% Non-Condensing
0 to 15,000m (0 to +50,000 ft)
14.56 x 6.69 x 7.87"
370 x 170 x 200 mm
23.8 lbs
34.2 lbs
39.2 lbs
10.8 Kgs
15.5 Kgs
17.8 Kgs
18.11 x 10.24 x 11.22"
460 x 260 x 285 mm
26.0 lbs
36.4 lbs
41.4 lbs
16.5 Kgs
11.8 Kgs
18.8 Kgs