Para systems PRO500LCD User Manual

Minuteman pro-lcd series ups

Advertisement

Quick Links

PRO-LCD
Series UPS
User's Manual
Para Systems, Inc.
1455 Lemay Dr.
Carrollton, TX 75007
Phone: 1-972-446-7363
Fax: 1-972-446-9011
Internet: minutemanups.com
UPS Sizing: sizemyups.com
PN - 34000407 R2

Advertisement

loading
Need help?

Need help?

Do you have a question about the PRO500LCD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Para systems PRO500LCD

  • Page 1 PRO-LCD Series UPS User's Manual Para Systems, Inc. 1455 Lemay Dr. Carrollton, TX 75007 Phone: 1-972-446-7363 Fax: 1-972-446-9011 Internet: minutemanups.com UPS Sizing: sizemyups.com PN - 34000407 R2...
  • Page 2: Table Of Contents

    Introduction Controls and Indicators Installation Operation Troubleshooting Replacing the Battery Obtaining Service Specifications Limited Product Warranty A1. Declaration of Conformity © Copyright 2011 All rights reserved. All MINUTEMAN trademarks are property of Para Systems, Inc. Other trademarks are property of their respective owners.
  • Page 3: Installation

    20 amperes maximum branch circuit over-current pro- tection in accordance with the National Electric Code, ANSI/NFPA Please read this manual before installing your PRO-LCD Tower Series UPS, models PRO500LCD, PRO700LCD, PRO1100LCD, PRO1500LCD as it pro- CAUTION! To reduce the risk of electrical shock with the installa-...
  • Page 4: Operation

    NOTE: These UPSs are shipped with the batteries disconnected. The batter- harmonic distortion and maximum single harmonic as below: ies must be connected before putting these UPSs into service. Refer to Sec- PRO500LCD Total harmonic 57.3% Single harmonic 43.0% tion 3 "Installation" for connecting the batteries.
  • Page 5 Input Power Plug Output Power Receptacles 6. Overload Icon: Illuminates when the amount of load attached to the UPS exceeds its power rating, PRO500LCD PRO700LCD 6-NEMA 5-15R Battery Backup & Surge 7. UPS Parameters and Error codes: NEMA 5-15P W/10 ft cord...
  • Page 6 FIG. 1 INSTALLATION PLACEMENT FIG. 2 This UPS series is only intended to be install in an indoor temperature con- trolled environment that is free of conductive contaminants. DO NOT operate the UPS in: extremely dusty and/or unclean areas, locations near heating de- vices, water or excessive humidity, or where the UPS is exposed to direct sunlight.
  • Page 7 CHECKING THE SITE WIRING FAULT After plugging the UPS into the wall outlet, check the LCD screen on the front panel of the UPS for a Site Wiring Fault (S.L.F). If the S.L.F is illuminated, the UPS is plugged into an improperly wired wall outlet. If the UPS indicates a Site Wiring Fault (S.L.F), have a Qualified Electrician correct the problem.
  • Page 8 SCROLL BUTTON LOW BATTERY WARNING Press the Scroll Button to scroll through the UPS parameters. The UPS pa- When the batteries reach the predetermined level, the alarm will sound two rameters are displayed on the LCD screen. beeps every five seconds and the Battery Bar Graph will display the remaining LCD SCREEN battery capacity.
  • Page 9 REPLACING THE BATTERY Possible Cause What To Do Symptom (QUALIFIED SERVICE PERSONNEL ONLY) On/Off/Test button not Press, hold and then release UPS will not turn on Please read all of the WARNINGS and CAUTIONS before attempting to service the On/Off button to start UPS pressed the batteries.
  • Page 10 8. Disconnect the Battery positive (red) wire. 9. Disconnect the Battery negative (black) wire. acid batteries. Caution: Do not short the Battery positive wire to the Battery negative wire. 10. Remove the two screws for the battery retaining bracket. PRO500LCD PRO700LCD PRO1100LCD PRO1500LCD Model # 11.
  • Page 11: Troubleshooting

    13. Slide the new battery module into the UPS. 14. Re-install the battery retaining bracket. 15. Re-install the two screws for the battery retaining bracket. 16. Verify proper polarity. Reconnect the battery negative (black) wire to the battery negative (black) terminal. 17.
  • Page 12: Specifications

    Battery Module Part # BM0048 BM0051 BM0049 BM0050 SYSTEM SPECIFICATIONS Runtime: Full Load (minutes) Runtime: Half Load (minutes) Model Number PRO500LCD PRO700LCD PRO1100LCD PRO1500LCD SURGE PROTECTION AND FILTERING Topology Line-Interactive, Simulated Sine Wave Surge Energy Rating 760 J Surge Current Capability...
  • Page 13: A1. Declaration Of Conformity

    Type of Equipment: Uninterruptible Power Supplies (UPS) The warranty shall be void if (a) the equipment is damaged by the customer, is improperly used, Model No: PRO500LCD, PRO700LCD, PRO1100LCD, PRO1500LCD is subjected to an adverse operating environment, or is operated outside the limits of its electrical specifications;...