Configuration Work Sheet (Ph) - Emerson Rosemount 1054B Instruction Manual

Microprocessor ph/orp analyzer
Table of Contents

Advertisement

MODEL 1054B pH/ORP
Use this work sheet to assist in the configuration of the analyzer.
A. Alarm 1 Setup (AL1)
1. Alarm Configuration (On/OFF)
2. High or Low (H-L) (Hi/Lo)
3. Hysteresis (HYS)
4. Delay Time On (don)
5. Delay Time Off (doF)
B. Alarm 2 Setup (AL2)
1. Alarm Configuration (On/FLt/OFF)
2. High or Low (H-L) (Hi/Lo)
3. Hysteresis (HYS)
4. Delay Time On (don)
5. Delay Time Off (doF)
C. Interval Timer (I I n n t t )
1. Active Status (tOn) (oFF/on)
2. Interval Time (int)
3. Count (cnt)
4. On Time (ont)
5. Off Time (OFt)
6. Duration (dur)
D. Temperature Setup (t-C)
1. Display Temperature (d-t) ( o C/ o F)
2. Automatic Temperature
Compensation (Atc) (on/oFF)
a. Manual Temp. Value
E. Current Output Setup (OUt)
1. mA Output (CUr) (020/420)
2. Display Current Output (d-O) (Pct/doc)
3. Dampen Current Output (dPn)
F. Electrode Diagnostics Setup (InP)
1. Temp compensated impedance (rES)
2. Impedance increase before calibration (CAL)
3. Cracked glass impedance low limit (SHt)
4. Aged electrode impedance high limit (OId)
G. Default Setup (dFt)
1. Relay 1 Default (rL1) (non/oFF/on)
2. Relay 2 Default (rL2) (non/oFF/on)
3. Current Output Default (Cur) (non/cur)
H. Automatic Buffer Mode (AbF)
1. Configuration (on/off)
I. Keyboard Security Setup (COd)
1. Keyboard Security Required
2. Keyboard Security Not Required
Alarm Setpoints
1. Alarm 1 (SP 1)
2. Alarm 2 (SP 2)
Current Output
1. Zero (0 or 4 mA) (LO)
2. F.S. (20 mA) (HI)
20
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
TABLE 4-1. Configuration Work Sheet (pH)
RANGE
0-2.0 pH
0-255 sec.
0-255 sec.
0-2.0 pH
0-255 sec
0-255 sec
Minimum 10 Minutes
1 to 60
0 to 299 sec
0 to 299 sec
0 to 299 sec
-10°C to 125°C
0-255 sec.
(on/oFF)
20-200%
5-600 megohms
200-1999 megohms
001-999
000
0-14 pH
0-14 pH
0-14 pH
0-14 pH
Date: ____________________
FACTORY SET
On
Lo
0 pH
000 Seconds
000 Seconds
On
Hi
0 pH
000 Seconds
000 Seconds
oFF
10 Seconds
5
1 Second
1 Second
2 Seconds
*C
on
420
doc
0.0 Seconds
oFF
20%
20 megohms
1000 megohms
non
non
non
on
_
000
0.00 pH
14.00 pH
0.00 pH
14.00 pH
SECTION 4.0
CONFIGURATION
USER SET
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________