Compaq PORTABLE 386 Maintenance And Service Manual page 44

Personal computer with plasma display
Hide thumbs Also See for PORTABLE 386:
Table of Contents

Advertisement

Error
Code
Error Description
------------------------------------------------------------------------------
1716 - xx
Fixed Disk Drive Conditional
Format Test
1716 - 01
Exceeded maximum soft error
limit.
1716 - 02
Exceeded maximum hard error
limit.
1716 - 05
Failed to reset controller.
1716 - 06
Fatal error while reading.
1716 - 07
Fatal error while writing.
1716 - 08
Failed compare of write/
read buffers.
1716 - 09
Failed to format a cylinder.
1716 - 40
Cylinder 0 failed.
1716 - 42
Failed recalibrate.
1716 - 55
Cylinder 1 error.
1716 - 58
Failed to write sector
buffer.
------------------------------------------------------------------------------
Error
Code
Error Description
------------------------------------------------------------------------------
1716 - 59
Failed to read sector
buffer.
1716 - 60
Failed to compare sector
buffer.
1716 - 65
Exceeded maximum bad sector
per track.
1716 - 66
Failed to initialize drive
parameter.
1716 - 70
Failed translate mode.
1716 - 71
Failed nontranslate mode.
1716 - 72
Exceeded maximum bad track
limit.
1716 - 73
Previously exceeded maximum
bad track limit.
Recommended Action
The following steps apply to error
codes 1700 - xx through 1717 - 73:
1.
Check the system board jumper
settings and retest
(see Chapter 9, "Jumper and
Switch Settings").
2.
Replace the fixed disk drive
signal and power cables and
retest.
3.
Replace the fixed disk drive
and retest.
4.
Replace the system board and
retest.
Recommended Action
The following steps apply to error
codes 1700 - xx through 1717 - 73:
1.
Check the system board jumper
settings and retest
(see Chapter 9, "Jumper and
Switch Settings").
2.
Replace the fixed disk drive
signal and power cables and
retest.
3.
Replace the fixed disk drive
and retest.
4.
Replace the system board and
retest.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents