Compaq PORTABLE 386 Maintenance And Service Manual page 25

Personal computer with plasma display
Hide thumbs Also See for PORTABLE 386:
Table of Contents

Advertisement

test failed
102 - 11
Numeric coprocessor
speed test failed
102 - 12
Numeric coprocessor
pattern test failed
102 - 14
Switch indicates no
coprocessor present
102 - 15
Coprocessor is inoperative
or socket is unoccupied
------------------------------------------------------------------------------
Error
Code
Error Description
------------------------------------------------------------------------------
103 - 01
Direct memory access page
registers test failed
103 - 02
Direct memory access byte
controller test failed
103 - 03
Direct memory access word
controller test failed.
104 - 01
Interrupt controller master
test failed.
104 - 02
Interrupt controller slave
test failed.
104 - 03
Interrupt controller
software RTC is inoperative.
105 - 01
Port 61, bit 6 not at zero.
105 - 02
Port 61, bit 5 not at zero.
105 - 03
Port 61, bit 3 not at zero.
105 - 04
Port 61, bit 1 not at zero.
------------------------------------------------------------------------------
Error
Code
Error Description
------------------------------------------------------------------------------
105 - 05
Port 61, bit 0 not at zero.
105 - 06
Port 61, bit 5 not at one.
105 - 07
Port 61, bit 3 not at one.
105 - 08
Port 61, bit 1 not at one.
105 - 09
Port 61, bit 0 not at one.
105 - 10
Port 61 I/O test failed.
105 - 11
Port 61, bit 7 not at zero.
and retest.
Recommended Action
Replace the system board and
retest for error codes 103 - 01
through 113 - 01.
Recommended Action
Replace the system board
and retest for error codes
103 - 01 through 113 - 01.

Hide quick links: