soft error limit.
1703 - 04
Previously exceeded maximum
hard error limit.
1703 - 05
Failed to reset controller.
1703 - 06
Fatal error while reading.
1703 - 07
Fatal error while writing.
1703 - 08
Failed compare of write/
read buffers.
1703 - 40
Cylinder 0 error.
1703 - 55
Cylinder 1 error.
1703 - 63
Failed soft error rate.
1703 - 65
Exceeded maximum bad sector
per track.
1703 - 67
Failed to write long.
------------------------------------------------------------------------------
Error
Code
Error Description
------------------------------------------------------------------------------
1703 - 68
Failed to read long.
1703 - 70
Failed translate mode.
1703 - 71
Failed nontranslated mode.
1703 - 72
Exceeded maximum bad track
limit.
1703 - 73
Previously exceeded maximum
bad track limit.
1704 - xx
Fixed Disk Drive Random Seek
Test.
1704 - 01
Exceeded maximum soft error
limit.
1704 - 02
Exceeded maximum hard error
limit.
1704 - 03
Previously exceeded maximum
soft error limit.
1704 - 04
Previously exceeded maximum
hard error limit.
1704 - 05
Failed to reset controller.
settings and retest
(see Chapter 9, "Jumper and
Switch Settings").
2.
Replace the fixed disk drive
signal and power cables and
retest.
3.
Replace the fixed disk drive
and retest.
4.
Replace the system board and
retest.
Recommended Action
The following steps apply to error
codes 1700 - xx through 1717 - 73:
1.
Check the system board jumper
settings and retest
(see Chapter 9, "Jumper and
Switch Settings").
2.
Replace the fixed disk drive
signal and power cables and
retest.
3.
Replace the fixed disk drive
and retest.
4.
Replace the system board and
retest.