Compaq PORTABLE 386 Maintenance And Service Manual page 42

Personal computer with plasma display
Hide thumbs Also See for PORTABLE 386:
Table of Contents

Advertisement

1708 - 09
Format track bad failed.
1708 - 42
Recalibrate drive failed.
1708 - 43
Failed to format a cylinder
bad.
1708 - 58
Failed to write sector
buffer.
1708 - 59
Failed to read sector
buffer.
------------------------------------------------------------------------------
Error
Code
Error Description
------------------------------------------------------------------------------
1709 - xx
Fixed Disk Drive Reset
Controller Test
1709 - 05
Failed to reset controller.
1710 - xx
Fixed Disk Drive Park Head
Test
1710 - 45
Failed to get fixed disk
drive parameters from ROM.
1710 - 47
Failed to park heads.
1714 - xx
Fixed Disk Drive File
Write Test
1714 - 01
Exceeded maximum soft error
limit.
1714 - 02
Exceeded maximum hard error
limit.
1714 - 03
Previously exceeded maximum
soft error limit.
1714 - 04
Previously exceeded maximum
hard error limit.
1714 - 05
Failed to reset controller.
1714 - 06
Fatal error while reading.
------------------------------------------------------------------------------
Error
Code
Error Description
------------------------------------------------------------------------------
1714 - 07
Fatal error while writing.
1714 - 08
Failed compare of write/
read buffers.
Recommended Action
The following steps apply to error
codes 1700 - xx through 1717 - 73:
1.
Check the system board jumper
settings and retest
(see Chapter 9, "Jumper and
Switch Settings").
2.
Replace the fixed disk drive
signal and power cables and
retest.
3.
Replace the fixed disk drive
and retest.
4.
Replace the system board and
retest.
Recommended Action
The following steps apply to error
codes 1700 - xx through 1717 - 73:
1.
Check the system board jumper
settings and retest

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents