CAUTION:
Ensure that the cables inside the system are correctly installed and retained by the cable retention bracket before
installing the cooling fan assembly. Incorrectly installed cables may get damaged.
Steps
1
Align the guide rails on the cooling fan assembly with the standoffs on the system.
2
Lower the cooling fan assembly into the system until the cooling fan connectors engage with the connectors on the system board.
3
Press the release levers to lock the cooling fan assembly into the system.
Figure 52. Installing the middle cooling fan assembly
Next step
1
Follow the procedure listed in

Flex bays

Removing a NVMe drive bay or flex bay

Prerequisites
NOTE:
The procedure to remove the flex bay is identical to removing the NVMe drive bay.
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
3
Disconnect the slim optical-drive and the backplane cables.
4
Remove the backplane from NVMe drive bay or the flex
After working inside your
system.
Safety
instructions.
Before working inside your
system.
bay.