Cooling Fan Matrix; Removing A Middle Or Rear Cooling Fan - Dell EMC PowerEdge T640 D24XR Installation And Service Manual

Table of Contents

Advertisement

Mellanox CX4 SP 100 Gb NIC (6W1HY)
Mellanox DP 40 Gb QSFP NIC (C8Y42)
Intel QP 10 Gb Base-T NIC (K5V44)
Solarflare Sunspot DP 10Gb NIC (NPHCM)
Solarflare Nova DP 10Gb NIC (WY7T5)
Qlogic DP 10Gb V1 NIC (VCXN5)
Listed below are the restrictions for fan redundancy:
GPGPU configurations are not supported at 35deg. C of ambient or above.
Mellanox 100G NICs are not supported.
For information on the restriction for fresh air condition, see the
Specification section.

Cooling fan matrix

Table 29. Cooling fan matrix
Chassis
3.5 inch x 8
3.5 inch x 18
2.5 inch x 16
2.5 inch x 32
2.5 inch x 16 + NVMe
Fan redundancy, FA and
high cooling tier PCIe
card
GPGPU card

Removing a middle or rear cooling fan

The procedure for removing a standard and a high performance fans is identical.
Prerequisites
WARNING:
Opening or removing the system cover when the system is on may expose you to a risk of electric shock. Exercise
utmost care while removing or installing cooling fans.
CAUTION:
The cooling fans are hot swappable. To maintain proper cooling while the system is on, replace only one fan at a time.
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
Step
Press the release tab and lift the cooling fan out of the cooling fan assembly.
94
Installing and removing system components
FAN1, FAN2 (Standard
[STD])
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Safety
instructions.
Before working inside your
Expanded operating temperature restrictions
FAN3, FAN4, FAN5,
FAN6 (Standard [STD]/
High performance
[HPR])
-
Yes (STD)
-
-
Yes (STD)
Yes (STD)
Yes (HPR)
system.
topic in the Technical
FAN_EXT_R,
FAN_EXT_L
-
-
-
-
-
-
Yes
Fan configuration
Base configuration
Rich configuration
Base configuration
Base configuration
Rich configuration
Rich configuration
GPU configuration