How to Use Each Feature
SYSTEM MENU
● You can set operating sounds of key operation, Trim and Switch and the buzzer tones.
● You can set 5 steps of the volume and 7 types of tones.
1) Select [SYSTEM] with up and down key.
Determine with the Enter operation.
2) Select [BUZZER] with up and down key.
Determine with the Enter operation.
3) Setting Tone and Volume
You can switch between Tone (scales) and Volume (Sound Volume)
with up and down key. Select an item to change setting to adjust.
○ Setting Range: VOLUME OFF~5
TONE 1~7
○ Default: VOLUME 4
TONE 1
● You can change the voltage setting of the battery alarm of the transmitter.
● By selecting Type [DRYx4 (Batteries)/Ni-MH x4 (Nickel Metal Hydride)/Li-Fe x2 (Lithium Ferrite) /Li-Po x2
(Lithium Polymer),CUSTOM], you can set the alarm easily.
*When selecting CUSTOM with the Type, you can set ALERT VOLT that sets voltage to make Alarm go off
and LIMIT VOLT of the lower limite voltage.
1) Select [SYSTEM] with up and down key.
Determine with the Enter operation.
2) Select [BATTERY] with up and down key.
Determine with the Enter operation.
3) Setting TYPE
Set TYPE for the battery to be used with up and down key.
○ Setting Range: DRY x4 (AA x4)
Ni-MH x2 (Nickel Metal Hydride)
Li-Po x2 (Lithium Polymer)
Li-Fe x2 (Lithium Ferrite)
CUSTOM: ALERT VOLT:4.1 ~ 9.0v
: LIMIT VOLT:4.0 ~ 9.0v
○ Default:
DRYx4 (AA x4)
47
SYSTEM
BUZZER
ENTER
BACK
ENTER
BACK
BATTERY
ENTER
BACK
● You can set LCD contrast (intensity) and lighting mode of Back Light.
1) Select [SYSTEM] with up and down key. Determine with the Enter operation.
2) Select [LCD] with up and down key. Determine with the Enter operation.
3) Set LCD contrast (intensity), lighting mode of Back Light,
and language.
○ Setting Items: CONTRAST (Intensity of Display)
LIGHTS-MODE (Backlight Lighting Mode)
LIGHT-TIME (Backlight Lighting Time)
○Setting Range: CONTRAST:0~30
LIGHT-MODE:OFF /KEY-ON /ALWAYS
LIGHT-TIME:1~30sec
○ Default:
CONTRAST:15
LIGHT-MODE:KEY-ON
LIGHT-TIME:10sec
CALIBRATION
● Due to wearing and tearing of the internal mechanical elements over the usage time, the neutral position
and the operation angle might become off. In such case, you can correct the neutral positions and the
operation angle of the steering and the throttle.
1) Select [SYSTEM] with up and down key.
Determine with the Enter operation.
2) Select [CALIBRATION] with up and down key.
Determine with the Enter operation.
3) Select a channel to calibrate with up and down key.
Determine with the Enter operation.
4) When selecting [STEERING], operate the Enter with
the steering wheel in neutral, then operate
the steering wheel fully to left and right.
5) When entering the range, [OK] is displayed.
Operate following the display.
6) When calibration is done, [Executed] is displayed.
*If the throttle side also needs calibration, refer to the steering to set.
SUPPLEMENT
●Steering did not work correctly even if you did calibration.
Please contact with our distributor in your country.
Completed Calibration
LCD
ENTER
BACK
ENTER
BACK
YES
Select YES if calibration is OK