7.6 Installing an RRU on an IFS06

This section describes the process and precautions for installing an RRU on an IFS06.
Prerequisites
The hoist clamp on the main bracket is secured properly.
Context
Procedure
Step 1 Disassemble the RRU mounting kits, as shown in Figure 7-44.
Issue Draft B (2018-05-15)
Do not stand an RRU upright because the RF ports cannot support the weight of the RRU.
Place a foam pad or cardboard under an RRU to protect the RRU housing from damage
during the installation.
The upper and lower adjustable beams on an IFS06 can be moved up and down to fit for
heights of RRUs.
RRUs can be installed on an IFS06 when the ambient temperature is higher than or equal
to the lowest operating temperature of the RRUs and at least 5° C (41° F) lower than the
highest working temperature of the RRU. In this scenario, the IFS06 supports at least
three RRUs. The IFS06 supports a maximum of six RRUs when the ambient temperature
is higher than or equal to the lowest operating temperature of the RRUs and at least 10° C
(50° F) lower than the highest operating temperature of the RRUs.
For details about the operating temperature of the RRUs, see section "Technical Specifications of RRUs"
in Base Station Technical Description.
Install RRUs from bottom to top and from left to right.
This section describes how to install an RRU in height-unrestricted scenarios. The
procedure for installing an RRU in height-restricted scenarios is the same as that in
height-unrestricted scenarios.
When installing the pole mounting kit, use the M10x50 bolts delivered with the IFS06.
Rubber washers are easily compressed or broken, whereas do not need to be replaced.