3.
Step 5 Strip the specified length of the sheath off the power cable to expose the intact shield layer, as
shown in Figure 11-8.
Figure 11-8 Stripping the sheath off the power cable
Each core wire is exposed outside the female connector (pressfit type) for 1.5 mm (0.059 in.),
as shown in Figure 11-9.
Figure 11-9 Inserting core wires into the female connector (pressfit type)
----End
Issue Draft B (2018-05-15)
After the core wires are installed, ensure that each core wire is securely installed after
being dragged with a torque of 30 N· m and all copper wires are inserted in the connector
terminal socket.