Installing An Rru Pgnd Cable - Huawei RRU5303 Installation Manual

Table of Contents

Advertisement

RRU5303
Installation Guide
Cable
Optic Cable
RRU RF
Jumper
RRU AISG
Multi-Wire
Cable
RRU AISG
Extension Cable

8.5 Installing an RRU PGND Cable

This section describes the procedure for installing an RRU PGND cable.
Context
The cross-sectional area of an RRU PGND cable is 16 mm
OT terminal at one end and an M8 terminal at the other end.
Issue Draft B (2018-05-15)
One End
Connector
4.3-10 straight
male connector
DB9 waterproof
male connector
Standard AISG
male connector
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
The Other End
Installation
Connector
Position
the RRU
CPRI1 port on
the RRU
RF ports on
4.3-10 straight
the RRU
male connector
or DIN male
connector
NOTICE
Select cables
based on the
type of the
connector at the
other end of the
cable on live
networks.
RET port on
Standard AISG
the RRU
female
connector
Standard
Standard AISG
AISG female
female
connector on
connector
the AISG
multi-wire
cable
2
(0.025 in.
8 Installing RRU Cables
Installation
Position
board in the
BBU or CPRI1
port on the
upper-level
RRU
CPRI0 port on
the lower-level
RRU or CPRI
port on a board
in the BBU
Antenna system
Standard AISG
male connector
on the RCU or
on the AISG
extension cable
Standard AISG
male connector
on the RCU
2
). The cable has an M6
99

Advertisement

Table of Contents
loading

Table of Contents