Power Supply Unit Indicator Codes - Dell EMC E39S Series Installation And Service Manual

Table of Contents

Advertisement

Table 13. NIC indicator codes
Status
Link and activity indicators are off.
Link indicator is green, and activity indicator is blinking
green.
Link indicator is amber, and activity indicator is blinking
green.
Link indicator is green, and activity indicator is off.
Link indicator is amber, and activity indicator is off.
Link indicator is blinking green, and activity is off.

Power supply unit indicator codes

AC power supply units (PSUs) have an illuminated translucent handle that serves as an indicator. The DC PSUs have an LED that serves
as an indicator. The indicator shows whether power is present or if a power fault has occurred.
Figure 11. AC PSU status indicator
1. AC PSU status indicator/handle
Table 14. AC PSU status indicator codes
Power indicator codes
Green
Blinking amber
Not illuminated
Blinking green
Blinking green and turns off When hot-plugging a PSU, the PSU handle blinks green five times at a rate of 4 Hz and turns off. This
Condition
A valid power source is connected to the PSU and the PSU is operational.
Indicates a problem with the PSU.
Power is not connected to the PSU.
When the firmware of the PSU is being updated, the PSU handle blinks green.
CAUTION:
Do not disconnect the power cord or unplug the PSU when updating firmware. If
firmware update is interrupted, the PSUs do not function.
indicates a PSU mismatch with respect to efficiency, feature set, health status, or supported voltage. If
two PSUs are installed, both the PSUs must have the same type of label; for example, Extended Power
Performance (EPP) label. Mixing PSUs from previous generations of PowerEdge servers is not supported,
even if the PSUs have the same power rating. This results in a PSU mismatch condition or failure to turn
the system on.
CAUTION:
When correcting a PSU mismatch, replace only the PSU with the blinking
indicator. Swapping the PSU to make a matched pair can result in an error condition and
unexpected system shutdown. To change from a high output configuration to a low output
configuration or vice versa, you must turn off the system. AC PSUs support both 240 V and
120 V input voltages with the exception of Titanium PSUs, which support only 240 V. When
two identical PSUs receive different input voltages, they can output different wattages, and
trigger a mismatch.
Condition
The NIC is not connected to the network.
The NIC is connected to a valid network at its maximum port speed, and
data is being sent or received.
The NIC is connected to a valid network at less than its maximum port
speed, and data is being sent or received.
The NIC is connected to a valid network at its maximum port speed, and
data is not being sent or received.
The NIC is connected to a valid network at less than its maximum port
speed, and data is not being sent or received.
NIC identify is enabled through the NIC configuration utility.