Remark:
a)
t1: ENA must be ahead of DIR by at least 5s. Usually, ENA+ and ENA- are NC (not connected). See
"Connector P1 Configurations" for more information.
b)
t2: DIR must be ahead of PUL effective edge by 5s to ensure correct direction;
c)
t3: Pulse width not less than 2.5s;
d)
t4: Low level width not less than 2.5s.
11. Protection Functions
To improve reliability, the drive incorporates some built-in protections features.
Time(s) of
Priority
Blink
1st
1
2nd
2
3nd
3
When above protections are active, the motor shaft will be free or the red LED blinks. Reset the drive by repowering it
to make it function properly after removing above problems.
Sequence wave of red LED
DMA860E Digital Stepper Drive User Manual
Description
Over-current protection activated when peak
current exceeds the limit.
Over-voltage protection activated when drive
working voltage is greater than 160VDC
Reserved.