Contents Contents Table of Contents Dynamic current setting ................10 Standstill current setting................10 1. Introduction, Features and Applications..............1 8. Wiring Notes ......................10 Introduction ......................1 9. Typical Connection....................11 Features ......................... 1 10. Sequence Chart of Control Signals ............... 11 Applications ......................
Electrical Specifications (T = 25℃/77℉) Introduction DM432C The DM432C is a versatility fully digital stepping driver based on a DSP with advanced control Parameters Typical Unit algorithm. The DM432C is the next generation of digital stepping motor controls. It brings a Output current 3.2 (2.3 RMS)
DM432C Digital Stepping Driver Manual V1.0 Operating Environment and other Specifications Selecting Active Pulse Edge and Control Signal Mode The DM432C supports PUL/DIR and CW/CCW modes and pulse active at rising or falling edge. See Cooling Natural Cooling or Forced cooling Avoid dust, oil fog and corrosive gases more information about these settings in Section 13.
5. Connecting the Motor motors should be run at only 70% of their rated current to prevent over heating. The DM432C can drive any 2-pahse and 4-pahse hybrid stepping motors. Connections to 4-lead Motors 4 lead motors are the least flexible but easiest to wire. Speed and torque will depend on winding Figure 6: 6-lead motor full coil (higher torque) connections inductance.
7. Selecting Microstep Resolution and Driver Output Current The DM432C can match medium and small size stepping motors (from NEMA frame size 14 to 23) made by Leadshine or other motor manufactures around the world. To achieve good driving Microstep resolutions and output current are programmable, the former can be set from full-step to performances, it is important to select supply voltage and output current properly.
Low level width not less than 2.5µs. 11. Protection Functions To improve reliability, the driver incorporates some built-in protection functions. The DM432C uses one RED LED to indicate what protection has been activated. The periodic time of RED is 3 s (seconds), and how many times the RED turns on indicates what protection has been activated.
DM432C Digital Stepping Driver Manual V1.0 DM432C Digital Stepping Driver Manual V1.0 Protection Indications Control signal is too weak Control signal is interfered Priority Time(s) of ON Sequence wave of RED LED Description Erratic motor motion Wrong motor connection Over-current protection...
This section will provide an overview of connection and basic setup instructions for Leadshine’s digital stepping driver DM432C using the ProTuner software. These instructions will walk you through the following steps necessary to start up your driver and motor. This section is intended for setting up the driver with the ProTuner.
Page 11
DM432C Digital Stepping Driver Manual V1.0 DM432C Digital Stepping Driver Manual V1.0 Figure 14: Installation folder settings Figure 16: Installation information summarization Figure 15: Shortcut folder setting Figure 17: Installing the ProTuner Set the “Shortcut Folder” in Figure 15 and continue to install the ProTuner by following Figure 16 and Figure 17.
Ø Option Turn on the power supply, the green (Power) LED will light. The DM432C has default parameters The user can choose three drop-down menus by clicking “Option”, including Com Config, stored in the driver. If the system has no hardware and wirings problem, the motor should be locked SaveToDriver and Exit.
DM432C Digital Stepping Driver Manual V1.0 DM432C Digital Stepping Driver Manual V1.0 Exit: Exit the ProTuner. Com Config Window Figure 22: Current Tuning window Figure 21: RS232 communication configuration window Ki: Integral Gain. Integral Gain helps the driver to overcome static current errors. A low or zero Serial Port: Select the serial communication port to which the driver is connected.
The Notes: DM432C driver provides robust anti-resonance control to stop the vibrations and maintain equilibrium. This feature requires that the driver be configured with respect to the total inertia in the system. If set However, if the user does not want to tune the current loop after changing a different stepping motor, improperly, the effectiveness of the feature may be diminished.
DM432C Digital Stepping Driver Manual V1.0 DM432C Digital Stepping Driver Manual V1.0 ResonanceArea: Parameters for 3 resonance area. Usually between 2.4rps and 4.8rps. Default making it more difficult to find proper adjustment values. Optimum AMP(s) and Phase(s) values may Amp3 and Phase3 values are 128.
Page 16
DM432C Digital Stepping Driver Manual V1.0 DM432C Digital Stepping Driver Manual V1.0 OverCurrent: Over-current Protection. Protection will be activated when continuous current exceeds 16A. OverVoltage: Over-voltage Protection. When power supply voltage exceeds 42±1 VDC, protection will be activated. PhaseErr: Phase Error Protection. Motor power lines wrong & not connected will activate this protection.
Please include a written description of the problem along with contact name and address. Send failed product to distributor in your area or: Leadshine Technology Co., Ltd. 3/F, Block 2, Nanyou Tianan Industrial Park, Nanshan Dist, Shenzhen, China. Also enclose information regarding the circumstances prior to product failure.