11. Protection Functions

To improve reliability, the drive incorporates some built-in protections features.
Time(s) of
Priority
Blink
1
1st
2
2nd
3
3nd
When above protections are active, the motor shaft will be free or the red LED blinks. Reset the drive by repowering it
to make it function properly after removing above problems.
Sequence wave of red LED
DM542E Digital Stepper Drive User Manual
Description
Over-current protection activated when peak
current exceeds the limit.
Over-voltage protection activated when drive
working voltage is greater than 60VDC
Reserved.