Output Current Configurations; Dynamic Current Configurations; Idle Current Configuration; Automatic Motor Matching & Self Configuration - Leadshine Technology DMA860E User Manual

2-phase digital stepper drive
Table of Contents

Advertisement

7.2 Output Current Configurations

For a given motor, higher drive current will make the motor to output more torque, but at the same time causes more
heating in the motor and drive. Therefore, output current is generally set to be such that the motor will not overheat for
long time operation. Since parallel and serial connections of motor coils will significantly change resulting inductance
and resistance, it is therefore important to set drive output current depending on motor phase current, motor leads and
connection methods. Phase current rating supplied by motor manufacturer is important in selecting drive current,
however the selection also depends on leads and connections.
The first three bits (SW1, 2, 3) of the DIP switch are used to set the dynamic current. Select a setting closest to your
motor's required current.

7.2.1 Dynamic Current Configurations

Peak Current
2.40A
3.08A
3.77A
4.45A
5.14A
5.83A
6.52A
7.20A
Notes: Due to motor inductance, the actual current in the coil may be smaller than the dynamic current setting,
particularly under high speed condition.

7.2.2 Idle Current Configuration

SW4 is used to set motor idle current percentage. At OFF position it means the standstill current is set to be 50% of the
selected output current. At ON position it means standstill current is set to be the same as the selected dynamic current.
The current automatically reduced to 50% of the selected dynamic current 0.4 second after the last pulse.
7.3 Automatic Motor Matching & Self Configuration
When powered on a DMA860E will automatically configure itself with the best settings to match the driven stepper
motor for optimal performance. No action is needed.

8. Wiring Notes

In order to improve anti-interference performance of the drive, it is recommended to use twisted pair shield cable.
To prevent noise incurred in PUL/DIR signal, pulse/direction signal wires and motor wires should not be tied up
together. It is better to separate them by at least 10 cm, otherwise the disturbing signals generated by motor will
easily disturb pulse direction signals, causing motor position error, system instability and other failures.
If only one power supply serves multiple DMA860E drives, separately connecting the drives to the power supply
is recommended instead of daisy-chaining.
It is prohibited to pull and plug connector P2 while the drive is powered ON, because there is high current flowing
RMS Current
1.70A
2.18A
2.67A
3.15A
3.64A
4.12A
4.61A
5.09A
DMA860E Digital Stepper Drive User Manual
SW1
SW2
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
SW3
ON
ON
ON
ON
OFF
OFF
OFF
OFF
Page | 8

Advertisement

Table of Contents
loading