Note
f When the [DISPLAY OPTION] menu → [BACKUP INPUT SETTING] (x page 108) → [BACKUP INPUT MODE] is set to anything other
than [OFF], and the power was turned off with the secondary input at the previous use, the projection is started with the primary input even if
[STARTUP INPUT SELECT] is set to [LAST USED].

[DATE AND TIME]

Set the time zone, date, and time of the built-in clock of the projector.
Setting the time zone
1)
Press as to select [DATE AND TIME].
2)
Press the <ENTER> button.
f The [DATE AND TIME] screen is displayed.
3)
Press as to select [TIME ZONE].
4)
Press qw to switch [TIME ZONE].
Setting the date and time manually
1)
Press as to select [DATE AND TIME].
2)
Press the <ENTER> button.
f The [DATE AND TIME] screen is displayed.
3)
Press as to select [ADJUST CLOCK].
4)
Press the <ENTER> button.
f The [ADJUST CLOCK] screen is displayed.
5)
Press as to select an item, and press qw to set the local date and time.
6)
Press as to select [APPLY], and press the <ENTER> button.
f The setting of the date and time will be completed.
Setting the date and time automatically
1)
Press as to select [DATE AND TIME].
2)
Press the <ENTER> button.
f The [DATE AND TIME] screen is displayed.
3)
Press as to select [ADJUST CLOCK].
4)
Press the <ENTER> button.
f The [ADJUST CLOCK] screen is displayed.
5)
Press as to select [NTP SYNCHRONIZATION], and press qw to change the setting to [ON].
6)
Press as to select [APPLY], and press the <ENTER> button.
f The setting of the date and time will be completed.
Note
f To set the date and time automatically, the projector must be connected to the network.
f If synchronization with the NTP server fails just after [NTP SYNCHRONIZATION] is set to [ON], [NTP SYNCHRONIZATION] will return to
[OFF]. If [NTP SYNCHRONIZATION] is set to [ON] while the NTP server is not set, [NTP SYNCHRONIZATION] will return to [OFF].
f Access the projector via a web browser to set the NTP server. Refer to "[Adjust clock] page" (x page 186) for details.
f The [TIME ZONE] setting is reset to the factory default when [ALL USER DATA] is executed from the [PROJECTOR SETUP] menu →
[INITIALIZE] (x page 158). However, the date and time based on the local date and time setting (Coordinated Universal Time, UTC,
Universal Time, Coordinated) will be maintained without being initialized.