[ECO]
*1
[LONG LIFE1]
*1
[LONG LIFE2]
*1
[LONG LIFE3]
*1
[USER1]
[USER2]
[USER3]
*1 The runtime is estimated when the [PICTURE] menu → [DYNAMIC CONTRAST] is set to [3].
5)
Press as to select [APPLY].
6)
Press the <ENTER> button.
7)
When the confirmation screen is displayed, press qw to select [OK], and press the <ENTER> button.
Note
f The [OPERATING MODE] setting will not return to the factory default even when [ALL USER DATA] is executed from the [PROJECTOR
SETUP] menu → [INITIALIZE] (x page 158).
f Set [OPERATING MODE] to anything other than [ECO], [LONG LIFE1], [LONG LIFE2], or [LONG LIFE3] when using the projector at an
altitude of 2 700 m (8 858') or higher above sea level.
f If the runtime exceeds 20 000 hours, replacement of the components inside the projector may be required. Consult your dealer for details.
Setting [MAX LIGHT OUTPUT LEVEL]
Adjust the maximum level to correct screen brightness according to the changes in brightness of the light source.
1)
Press as to select [OPERATION SETTING].
2)
Press the <ENTER> button.
f The [OPERATION SETTING] screen is displayed.
3)
Press as to select [MAX LIGHT OUTPUT LEVEL].
4)
Press qw to adjust.
Operation
Press w.
Press q.
5)
Press as to select [APPLY].
6)
Press the <ENTER> button.
7)
When the confirmation screen is displayed, press qw to select [OK], and press the <ENTER> button.
Note
f When [OPERATING MODE] is set to [NORMAL], [ECO], [LONG LIFE1], [LONG LIFE2], or [LONG LIFE3], the item of [MAX LIGHT OUTPUT
LEVEL] cannot be adjusted.
f When the [PROJECTOR SETUP] menu → [BRIGHTNESS CONTROL] → [BRIGHTNESS CONTROL SETUP] → [CONSTANT MODE] is
set to [AUTO] or [PC], the brightness is corrected using this setting.
f The [MAX LIGHT OUTPUT LEVEL] setting will not return to the factory default even when [ALL USER DATA] is executed from the
[PROJECTOR SETUP] menu → [INITIALIZE] (x page 158).
Setting [LIGHT OUTPUT]
Adjust the brightness of light source.
The [LIGHT OUTPUT] setting is synchronized with the [PROJECTOR SETUP] menu → [LIGHT OUTPUT]. The
most recent setting is reflected in both items.
1)
Press as to select [OPERATION SETTING].
2)
Press the <ENTER> button.
f The [OPERATION SETTING] screen is displayed.
Chapter 4 Settings — [PROJECTOR SETUP] menu
Set this item to increase the life of the light source though it will lower the luminance than [NORMAL].
The estimated runtime is approximately 24 000 hours.
Set this item to increase the life of the light source though it will lower the luminance than [ECO]. The
estimated runtime is approximately 43 000 hours.
Set this item to increase the life of the light source though it will lower the luminance than [LONG
LIFE1]. The estimated runtime is approximately 61 000 hours.
Set this item to increase the life of the light source though it will lower the luminance than [LONG
LIFE2]. The estimated runtime is approximately 87 000 hours.
Set [MAX LIGHT OUTPUT LEVEL] and [LIGHT OUTPUT] individually.
Increases the maximum level of brightness correction.
Decreases the maximum level of brightness correction.
Adjustment
Range of adjustment
8.0 % - 100.0 %