6.3.2. WDT for LP-22xx and LP-52xx

To Enable WDT working status, there are two steps to this process, which are described below.
(1) Refresh WDT source.
# echo timer > /sys/class/leds/beaglebone::wdt/trigger
(2) Enable WDT.
# echo 0 > /proc/hmistat/radiopower
To Disable WDT working status, there are two steps to this process, which are described below.
(1) Disable WDT.
# echo 1 > /proc/hmistat/radiopower
(2) Clear WDT refresh source.
# echo none > /sys/class/leds/beaglebone::wdt/trigger
AM335X-PAC Series User Manual
Copyright © 2021 ICP DAS Co., Ltd. All Rights Reserved.
//Refresh WDT
//Enable WDT
//Disable WDT
//Clear WDT Refresh Source