Table of Contents

Advertisement

Quick Links

INT-44HDX Installation and
FIRMWARE
IR OUT
1
2
1
2
HDMI INPUTS
IR ALL IN
Rev 170217
Operation Guide
ZONE 1
IR IN
RS232
3
4
1
COAX
TX
3
4
AUDIO
HDMI
HDB seT
L
INPUTS
1
2
3
OUTPUTS
ZONE 2
IR IN
IR IN
RS232
2
3
RX
COAX
TX
RX
AUDIO
R
HDMI
HDB seT
L
R
OUTPUTS
11675 Ridgeline Dr.
Colorado Springs, CO
80921
MENU
4
ALL
CLEAR
ZONE 3
ZONE 4
IR IN
RS232
RS232
4
COAX
TX
RX
COAX
TX
AUDIO
AUDIO
HDB seT
L
R
HDB seT
L
EDID
ENTER
TCP/IP
IR EYE
RX
R
RS232
24V DC
Toll-Free: 800-530-8998
Fax: 719-260-0075
supportlibav@libav.com

Advertisement

Table of Contents
loading

Summary of Contents for Intelix INT-44HDX-BSTK

  • Page 1 INT-44HDX Installation and Operation Guide INPUTS MENU EDID FIRMWARE CLEAR ENTER OUTPUTS TCP/IP IR OUT ZONE 1 ZONE 2 ZONE 3 ZONE 4 IR IN IR IN IR IN IR IN IR EYE RS232 RS232 RS232 RS232 COAX COAX COAX COAX AUDIO AUDIO...
  • Page 2: Important Safety Instructions

    INT-44HDX Installation Guide Important Safety Instructions 1. Read these instructions – All the safety and operating instructions should be read before this product is operated. 2. Keep these instructions – The safety and operating instructions should be retained for future reference. 3.
  • Page 3 INT-44HDX Installation Guide 26. When the apparatus is not in use or during its relocation, take care of the power cord and plugs; e.g. tie up the power cord with cable tie or similar. The tie must be free from sharp edges and the like that might cause abrasion of the power cord.
  • Page 4: Table Of Contents

    INT-44HDX Installation Guide Table of Contents Important Safety Instructions ����������������������������������������������������������������������������������������������������������������������������2 Product Overview ����������������������������������������������������������������������������������������������������������������������������������������������6 Package Contents ����������������������������������������������������������������������������������������������������������������������������������������������6 Front and Rear Panels ����������������������������������������������������������������������������������������������������������������������������������������7 Front Panel ���������������������������������������������������������������������������������������������������������������������������������������������������������� 7 Rear Panel ����������������������������������������������������������������������������������������������������������������������������������������������������������� 8 IR Remote ����������������������������������������������������������������������������������������������������������������������������������������������������������9 Control Routing Diagrams �������������������������������������������������������������������������������������������������������������������������������10 IR Routing ���������������������������������������������������������������������������������������������������������������������������������������������������������� 10 RS232 and TCP/IP to RS232 Routing ������������������������������������������������������������������������������������������������������������������...
  • Page 5 INT-44HDX Installation Guide Web Browser Control ���������������������������������������������������������������������������������������������������������������������������������������19 User Login ��������������������������������������������������������������������������������������������������������������������������������������������������������� 19 Matrix Routing - User ���������������������������������������������������������������������������������������������������������������������������������������� 19 Administrator Login ������������������������������������������������������������������������������������������������������������������������������������������ 20 Matrix Routing - Administrator ������������������������������������������������������������������������������������������������������������������������� 20 RS232 and TCP/IP Control ��������������������������������������������������������������������������������������������������������������������������������21 Routing Commands ������������������������������������������������������������������������������������������������������������������������������������������� 21 Preset Commands ��������������������������������������������������������������������������������������������������������������������������������������������� 22 Power Management �����������������������������������������������������������������������������������������������������������������������������������������...
  • Page 6: Product Overview

    Installation Guide Product Overview The Intelix INT-44HDX is a four input by four output HDBaseT/HDMI matrix switcher with HDCP 2.2 and UHD/30 video support. The matrix features advanced EDID and HDCP handling, including the ability to turn input HDCP compliance ON and OFF to ensure maximum functionality with a wide range of sources.
  • Page 7: Front And Rear Panels

    INT-44HDX Installation Guide Front and Rear Panels Front Panel INPUTS MENU EDID FIRMWARE CLEAR ENTER OUTPUTS Micro USB port for firmware updating Power indicator LED; IR receiver for matrix control via IR remote LCD screen Input select and LCD navigation buttons All button –...
  • Page 8: Rear Panel

    INT-44HDX Installation Guide Rear Panel TCP/IP IR OUT ZONE 1 ZONE 2 ZONE 3 ZONE 4 IR IN IR IN IR IN IR IN IR EYE RS232 RS232 RS232 RS232 COAX COAX COAX COAX AUDIO AUDIO AUDIO AUDIO RS232 HDMI HDB seT HDMI HDB seT...
  • Page 9: Ir Remote

    INT-44HDX Installation Guide IR Remote The included IR remote performs all of the functions available on the front panel of the INT-44HDX. Please see page 17 for information on controlling the matrix from the front panel and the IR remote. The remote control requires two AAA batteries, which are included.
  • Page 10: Control Routing Diagrams

    INT-44HDX Installation Guide Control Routing Diagrams IR Routing Out 1 IR In Out 4 IR In IR All In IR bridge 1 IR bridge 4 HDBT Out 1 HDBT Out 4 RS232 and TCP/IP to RS232 Routing 9600 baud TCP/IP In RS232 In Out 1 RS232 Out 4 RS232...
  • Page 11: Installation Instructions

    The HDBaseT ports provide 15 watts of Power over Ethernet to 48 volt based HDBaseT devices, which eliminates the need for a power supply with a compatible HDBaseT device. All Intelix branded HDBaseT receivers that accept remote power are compatible with the INT-44HDX.
  • Page 12: Connect Sources

    INT-44HDX Installation Guide Connect Sources Connect the source devices to HDMI inputs using HDMI cables that are less than or equal to 5 meters in length. For source devices that are further away, an HDMI extension device will be required to complete the connection. Connect Displays HDMI Outputs Connect the display devices to HDMI outputs using HDMI cables that are less than or equal to 5 meters in length.
  • Page 13: Connect Ir Control

    HDBaseT devices, and an IR input connection to control the matrix. For remote displays that require IR control, Intelix recommends using the DIGI-HD60C-R or DIGI-HDX-R. Only use the included IR receiver or the IR-AC IR adapter cable (sold separately) with the INT-44HDX4. The IR adapter cables allow third party controllers to connect directly to the IR input ports of the INT-44HDX.
  • Page 14: Connect Rs232 Control

    In addition to traditional RS232 control, the INT-44HDX has an advanced RS232 control mechanism which allows RS232 tunneling and routing through the HDBaseT output port to control remote devices. Intelix recommends using the DIGI-HD60C-R or DIGI-HDX-R for installations which require RS232 extension.
  • Page 15: Connect Tcp/Ip (Ethernet) Control

    INT-44HDX Installation Guide Connect TCP/IP (Ethernet) Control The INT-44HDX may be controlled via Ethernet with a third party control system or through a web browser interface. Additionally, the INT-44HDX has an advanced RS232 control mechanism which will transmit RS232 commands through the HDBaseT output port to control remote devices with a simple command string.
  • Page 16: Web Browser Control

    While the matrix is booting up, the front LCD panel will show the IP address of the matrix and the current version of firmware. After five seconds, it will show Intelix INT-44HDX. The backlight will go dark after five seconds.
  • Page 17: Basic Front Panel And Ir Remote Operation

    INT-44HDX Installation Guide Basic Front Panel and IR Remote Operation Basic Routing Setting a route using the front panel of the matrix will route the input signal to the selected output. To set a route using the front panel of the INT-44HDX: Press the desired input button (source).
  • Page 18: Ir Remote Operation

    INT-44HDX Installation Guide IR Remote Operation The button functions on the IR remote are identical to the buttons on the front panel of the INT-44HDX. Only input and output numbers 1 through 4 are used on the remote. The Standby button will send the matrix to a low power state. Pressing the Standby button a second time will restore the INT-44HDX to full power.
  • Page 19: Web Browser Control

    INT-44HDX Installation Guide Web Browser Control User Login Username: Password: Login INT-44HDX Open a web browser and go to the IP address of the INT-44HDX. The default IP address is 192.168.0.178. Type user in the Username field. Enter the password to gain control of the matrix. The default password is “user”. Press the Enter key on your keyboard or tablet to go to the matrix control screen.
  • Page 20: Administrator Login

    INT-44HDX Installation Guide Administrator Login Username: Password: Login INT-44HDX Open a web browser and go to the IP address of the INT-44HDX. The default IP address is 192.168.0.178. Type admin in the Username field. Enter the password to gain control of the matrix. The default password is “admin”. Press the Enter key on your keyboard or tablet to go to the matrix control screen.
  • Page 21: Rs232 And Tcp/Ip Control

    INT-44HDX Installation Guide RS232 and TCP/IP Control RS232 Settings: 9600 baud, 8 Data bits, 1 Stop bit, Parity = None TCP/IP Settings: User defined IP address (default IP address: 192.168.0.178), port 4001 There is a period (.) at the end of each command. These characters must be present for the command to process correctly.
  • Page 22: Preset Commands

    INT-44HDX Installation Guide Preset Commands The INT-44HDX can store up to 10 presets of predetermined video routes. Description Command Response Savex. Save to Fx Save the current routing as a preset. Values range from 0 through 9 Recallx. Recall From Fx Recall preset x Clearx.
  • Page 23: Advanced Front Panel And Ir Remote Operation

    INT-44HDX Installation Guide Advanced Front Panel and IR Remote Operation EDID Management The INT-44HDX has five built-in EDID settings for the inputs, but also allows copying the EDID information of an output device to the input of the matrix. Copy EDID from Output to Input To copy the EDID from output 3 to input 1: 1.
  • Page 24: System Query

    INT-44HDX Installation Guide System Query The INT-44HDX can provide basic system information through the front panel LCD. To check the current source going to an output, press and hold the output button for three seconds. To query the matrix status: 1.
  • Page 25: Ir Remote Operation

    INT-44HDX Installation Guide IR Remote Operation The button functions on the IR remote are identical to the buttons on the front panel of the INT-44HDX. The EDID copy command sequences follow the same procedures as the front panel command sequences. The Standby button will send the matrix to a low power state.
  • Page 26: Edid Settings

    INT-44HDX Installation Guide EDID Settings The default EDID for the inputs of the INT-44HDX is 1080p with stereo audio. In order to change the EDID information for an input, either activate one of the built-in EDID tables or use the EDID copy command functions via front panel, IR, RS232, TCP/IP or through the web browser setup interface (see page 28).
  • Page 27: Web Browser Configuration

    INT-44HDX Installation Guide Web Browser Configuration When changes are made on a setup tab, the Save button must be pressed for the changes to take effect. User Tab The Users setup screen provides options to change the Administrator and User passwords. The front panel can also be locked to prevent tampering from this screen.
  • Page 28: Hdcp And Edid Configuration Tab

    INT-44HDX Installation Guide HDCP and EDID Configuration Tab The Configuration setup screen has options to turn on and off the HDCP compliance flag for an input, select the audio input source for inputs 1 and 2, enable or disable the digital audio output, and copy the EDID from an output to an input.
  • Page 29: Rs232 And Tcp/Ip Configuration

    INT-44HDX Installation Guide RS232 and TCP/IP Configuration Front Panel Lock The front panel lock prevents digital video switching from being activated via the front panel. Description Command Response /%Lock; System Locked! Lock the front panel keys /%Unlock; System Unlock! Unlock the front panel keys HDBaseT and HDMI Audio Output Turn on and off the audio feed going to the HDMI and HDBaseT outputs.
  • Page 30: Power On Rs232 Routing To Hdbaset

    INT-44HDX Installation Guide Power On RS232 Routing to HDBaseT In addition to immediate transmission, the INT-44HDX can store commands to be broadcast when the matrix is powered on through the standby commands (PWON., STANBY., and PWOFF.). The format of the RS232 routing string is: /+<Y>/<B>:<$>. (The period at the end of the string is required.) <Y>...
  • Page 31: Rs232 And Tcp/Ip System Query

    INT-44HDX Installation Guide RS232 and TCP/IP System Query Routing Queries Description Command Response Statusy. x-> y Output y routing status (only 1 digit) Status. 1-> 1 Routing status of all outputs. 2-> 2 3-> 3 4-> 4 Signal Status Queries Description Command Response...
  • Page 32: Matrix Status Queries

    INT-44HDX Installation Guide Matrix Status Queries Description Command Response /*Type; INT-44HDX Get model number /^Version; V1.0.0 Check the software version %9961. Query system lock state System Locked! or System Unlock! %9962. Query standby state PWON STANDBY PWOFF %9964. IP:192.168.0.178 Query the IP address Display Control Queries If there are no PWON or PWOFF commands defined for an HDBaseT port, the response string will be: Port #: NO Data for the single command queries and Port # : NO Data when PWON or Port # : NO Data...
  • Page 33: Troubleshooting

    INT-44HDX Installation Guide Troubleshooting Matrix does not power on Verify power outlet is active. » Verify continuity in power cable. » Cannot view 4K (UHD) content Copy EDID from output to input. » Verify display is 4K (UHD) compatible. » Verify source device can output 4K (UHD) content.
  • Page 34: Technical Specifications

    INT-44HDX Installation Guide Technical Specifications Input/Output Connections HDMI Inputs Four (4) HDMI Type A Receptacle Four (4) 3.5mm TRS IR Outputs HDMI Outputs (Outputs 1 and 2 only) Two (2) HDMI Type A Receptacle HDBaseT Outputs Four (4) 8P8C Port (Shielded RJ45 Female) Digital Audio Outputs Four (4) RCA Connectors Analog Audio Outputs...
  • Page 35 INT-44HDX Installation Guide...
  • Page 36 Intelix is a brand of: 11675 Ridgeline Drive Colorado Springs, Colorado 80921 USA Phone: 719-260-0061 Fax: 719-260-0075 Toll-Free: 800-530-8998...

This manual is also suitable for:

Int-44hdx

Table of Contents