  • Page 1 FLX-3232 Installation and Operation Guide Rev 130701 8001 Terrace Ave Phone: 608-831-0880 Suite 201 Toll-Free: 866-462-8649 Middleton, WI 53562 Fax: 608-831-1833...
  • Page 2: Important Safety Instructions

    Do not block the air ventilation openings. Only mount the equipment per Intelix’s instructions.  Use only with the cart, stand, table, or rack specified by Intelix or sold with the equipment. When/if a cart is  used, use caution when moving the cart/equipment combination to avoid injury from tip-over.
  • Page 3: Table Of Contents

    FLX-3232 Installation Guide Table of Contents Overview ..................................5 Package Contents ............................5 Front Panel ..............................6 Rear Panel ..............................7 IR Remote ..............................7 Input Cards ................................8 Analog Video (FLX-RI4) ..........................8 DVI (FLX-DI4) .............................. 8 HDBaseT (FLX-BI4)............................ 8 HDMI (FLX-HI4A) ............................
  • Page 4 Matrix does not power on ........................25 Cannot view 3D content ........................25 Cannot hear surround sound audio ....................25 No video from HDBaseT input or output ..................25 FLX-3232 Chassis ............................. 26 FLX-BI4 ................................ 27 FLX-HI4A ..............................28 FLX-RI4 ............................... 29 FLX-DI4 ..............................30 FLX-BO4A ..............................
  • Page 5: Overview

    Ten programmable presets provide an efficient means of configuring the video and audio distribution for common usage patterns. The FLX-3232 was designed with flexibility in mind. There are over 80 possible input card to output card combinations. Since the system is modular, the system integrator can customize their installation per their customer’s needs and not the limitations of available hardware.
  • Page 6: Front Panel

    FLX-3232 Installation Guide Front Panel Menu Input (Top) Buttons Power LED/ IR Receiver Rack Handle LCD Status Output Menu Display Buttons (Bottom) Power LED – Indicates the matrix has proper input power. IR Receiver – For use with the included IR remote.
  • Page 7: Rear Panel

    AC Input – Standard IEC C14 inlet. Redundant power inlet – connect to [2] separate circuits, if the first circuit loses power, the matrix will switch automatically to the other circuit. IR Remote The included IR remote performs all of the functions available on the front panel of the FLX-3232.
  • Page 8: Input Cards

    FLX-3232 Installation Guide Input Cards The modular input cards are keyed on the right side to line up with the output cards and ensure they are installed correctly in the matrix. Analog Video (FLX-RI4) The HD15 inputs on the FLX-RI4 scale and convert a wide range of analog video signals to HD video resolutions, which can be routed to any available output.
  • Page 9: Hdmi (Flx-Hi4A)

    FLX-3232 Installation Guide HDMI (FLX-HI4A) The FLX-HI4 HDMI inputs can be routed to any available outputs. The HDMI inputs can accept video signals up to 1920x1200, including 3D and 48-bit Deep Color at 1080p. Additionally, audio signals from stereo up to 7.1 audio streams will pass through the matrix to supported outputs.
  • Page 10: Output Cards

    FLX-3232 Installation Guide Output Cards The modular output cards are keyed on the left side to line up with the input cards and ensure they are installed correctly in the matrix. DVI (FLX-DO4) The FLX-DO4 DVI-D outputs are HDMI and HDCP compliant and support CEC and DDC standards.
  • Page 11: Hdmi (Flx-Ho4A)

    FLX-3232 Installation Guide HDMI (FLX-HO4A) The FLX-HO4 HDMI outputs can be routed from any input in the matrix. The HDMI outputs can pass video signals up to 1920x1200, including 3D and 48-bit Deep Color at 1080p. Additionally, audio signals from stereo up to 7.1 audio streams will pass to supported HDMI output devices.
  • Page 12: Installation Instructions

    General I/O Card Installation to install the I/O cards. Rack Mounting Instructions The FLX-3232 requires three rack units (5 RU) of space. At least 2 inches of free air space is required on both sides of the FLX-3232 for proper side ventilation. Avoid mounting the FLX-3232 near a power amplifier or any other source of significant heat.
  • Page 13: Flx-Bi4 And Flx-Bo4A Wiring

    FLX-3232 Installation Guide 3. Slide the I/O card between the guide rails until it is firmly seated. 4. Secure the I/O card by tightening the thumb screws. 5. Connect the appropriate cabling to the I/O card. 6. Power on the matrix.
  • Page 14: Flx-Ri4 Wiring

    FLX-3232 Installation Guide To use the RS232 extension capabilities of the FLX-BI4 and FLX-BO4A, connect the TX, ground, and RX control signal wires to the removable 3-pole terminal block. Consult the manual of the control device(s) to determine which pins the TX/RX signals are carried on. Be sure to always connect TX to RX and RX to TX.
  • Page 15 FLX-3232 Installation Guide For component video, S-video, and composite video, a VGA to breakout cable is recommended. The FLX-RI4 comes with two FLX-RBOCA (component video breakout cable) and two FLX- RBOCB (composite and S-video breakout cable) cables. See FLX-RI4 Specific Commands on page 20 to define the operation of the inputs.
  • Page 16: Edid Management

    FLX-3232 Installation Guide EDID Management The stock EDID for the inputs of the FLX-3232 is 1280x1024 (computer video input) and 1080p with stereo audio (consumer video input). In order to change the EDID information for an input, the EDID copy command will need to be sent to the matrix via RS232 or TCP/IP.
  • Page 17: Front Panel And Ir Remote Operation

    2. Press THROUGH. IR Remote Operation The buttons on the IR remote are similar to the buttons on the front panel of the FLX-3232. The IR routing commands match those of the front panel, except multiple output routing is not possible.
  • Page 18: Third Party Control Setup

    Configuring the TCP/IP port is done via a web browser interface. A crossover cable is required for the initial setup. The default IP address is printed on a sticker on the side of the FLX-3232. Configure the computer to use the same network prefix as the IP address assigned to the matrix.
  • Page 19: Access The Web Browser With Defined Ip Address

    6. Press the LOGIN button. Pressing the Enter key will give a bad password error. 7. Click the System Info button to change the IP address. 8. Changing the dropdown option from Static to DHCP will allow the FLX-3232 to automatically obtain an IP address from a DHCP server on the network.
  • Page 20: Additional Options In Web Browser

    Additional Options in Web Browser Serial Info – Adjusts TCP/IP specific settings, including the default port (4001). a. Changing the baud rate settings has no effect on the RS232 port of the FLX-3232. b. The baud rate setting must remain at 9600.
  • Page 21: Rs232 And Tcp/Ip Commands

    FLX-3232 Installation Guide RS232 and TCP/IP Commands RS232 Settings: 9600 baud, 8 Data bits, 1 Stop bit, Parity = None TCP/IP Settings: User defined IP address, port 4001 There is either a period (.) or a semicolon (;) at the end of each command. These characters must be present for the command to process correctly.
  • Page 22: Preset Commands

    FLX-3232 Installation Guide Preset Commands Description Command Response Save the current routing as a preset. Values Savex. Save to Fx<CR><LF> range from 0 through 9 Recall preset x Recallx. Recall From Fx<CR><LF> Clear preset x Clearx. Examples: Save the current routing as preset 4.
  • Page 23: Hdcp Commands

    FLX-3232 Installation Guide HDCP Commands Description Command Response Turn HDCP Compliance off for input xx /%I/xx:0. /%I/xx:0.<CR><LF> Turn HDCP Compliance on for input xx /%I/xx:1. /%I/xx:1.<CR><LF> Example: Turn HDCP Compliance off for input 4 /%I/04:0. FLX-RI4 Specific Commands The input number values are dependent upon which slot the FLX-RI4 is inserted. If the input card is in the first input card slot, the input number values range from 01 through 04.
  • Page 24: Flx-Hi4A Specific Commands

    FLX-3232 Installation Guide FLX-HI4A Specific Commands The input number values are dependent upon which slot the FLX-HI4A is inserted. If the input card is in the first input card slot, the input number values range from 1 through 4. If the input card is in the second input card slot, the input number values range from 5 through 8.
  • Page 25: Troubleshooting

    FLX-3232 Installation Guide Troubleshooting Matrix does not power on Verify power outlet is active. Verify continuity in power cable. Cannot view 3D content Copy EDID from output to input. Verify display is 3D compatible. Verify source device can output 3D content.
  • Page 26: Flx-3232 Chassis

    ESD Protection 15kV Regulatory CE, RoHS Other Warranty 2 years Diagnostic Indicators LCD output status and power LED Included Accessories Installation Guide, IR Remote, RS232 Cable, Power Cable, Modular Metal Blank (16 ea), Rubber Feet (4 ea) and Intelix Pocket Screwdriver.
  • Page 27: Flx-Bi4

    -10° to +60° C (+14° to +140° F) Storage Humidity 20% to 90%, Non-condensing Other Warranty 2 years Matrix Switcher Compatibility FLX-8X8A, FLX-3232, FLX-3232, FLX-3232 HDBaseT Transmitter (A/V and Control) Compatibility DIGI-HDE-S, DIGI-HD60C-S HDBaseT Transmitter (A/V Only) Compatibility DIGI-HD70-S Infrared (IR) Emitter DIGIB-EMT...
  • Page 28: Flx-Hi4A

    FLX-3232 Installation Guide FLX-HI4A Technical Specifications I/O Connections HDMI Input Four (4) HDMI Type A Receptacle Connector Analog Audio In Four (4) 3 pole Euroblock Connectors Supported Audio and Video Maximum Video Compatibility Deep Color 48/36/30/24 Bit at 1080p, 3D...
  • Page 29: Flx-Ri4

    40 mm (15.75 in.) Male HD15 to three (3) Female RCA Connectors (Red, Green, Blue) FLX-RBOCB (2 ea) 40 mm (15.75 in.) Male HD15 to one (1) Female RCA Connector (Yellow) and one (1) Female S-Video Connector Other Warranty 2 years HDMI Matrix Switcher Compatibility FLX-8X8A, FLX-3232, FLX-3232, FLX-3232...
  • Page 30: Flx-Di4

    0° to +40° C (+32° to +104° F) Operating Humidity 20% to 90%, Non-condensing Storage Temperature -10° to +60° C (+14° to +140° F) Storage Humidity 20% to 90%, Non-condensing Other Warranty 2 years Matrix Switcher Compatibility FLX-8X8A, FLX-3232, FLX-3232, FLX-3232...
  • Page 31: Flx-Bo4A

    FLX-3232 Installation Guide FLX-BO4A Technical Specifications I/O Connections HDBaseT Port Four (4) 8P8C port (Shielded RJ45) Analog Audio Out Four (4) 3.5 mm TRS RS232 Four (4) 3 pole Euroblock Connectors Supported Audio and Video Maximum Video Compatibility at 70 m...
  • Page 32: Flx-Ho4A

    FLX-3232 Installation Guide FLX-HO4A Technical Specifications I/O Connections HDMI Input Four (4) HDMI Type A Receptacle Connector Analog Audio Out Four (4) 3 pole Euroblock Connectors Supported Video Maximum Video Compatibility Deep Color 48/36/30/24 Bit at 1080p, 3D Video Compliance...
  • Page 33: Flx-Do4

    0° to +40° C (+32° to +104° F) Operating Humidity 20% to 90%, Non-condensing Storage Temperature -10° to +60° C (+14° to +140° F) Storage Humidity 20% to 90%, Non-condensing Other Warranty 2 years Matrix Switcher Compatibility FLX-8X8A, FLX-3232, FLX-3232, FLX-3232...
  • Page 34: Digib-Emt

    FLX-3232 Installation Guide DIGIB-EMT Technical Specifications Signal Characteristics Wide-Band Infrared (IR) 30 KHz to 56 KHz at 5V DC reference Physical Characteristics Material, Emitter Housing Deep red translucent plastic Dimensions, Emitter Housing 6 mm x 9.5 mm x 15 mm (0.24 in. x 0.37 in. x 0.59 in.) Cable Length 2 m (6.56 ft)
  • Page 35 FLX-3232 Installation Guide This page intentionally left blank.
  • Page 36 FLX-3232 Installation Guide Thank you for your purchase. Please contact us with your questions and comments. Intelix 8001 Terrace Ave, Ste 201 Middleton, WI 53562 Phone: 608-831-0880 Toll Free: 866-462-8649 Fax: 608-831-1833 www.intelix.com intelix@intelix.com...

Table of Contents