Page 1
INT-44HDX Installation and Operation Guide INPUTS MENU EDID FIRMWARE CLEAR ENTER OUTPUTS TCP/IP IR OUT ZONE 1 ZONE 2 ZONE 3 ZONE 4 IR IN IR IN IR IN IR IN IR EYE RS232 RS232 RS232 RS232 COAX COAX COAX...
INT-44HDX Installation Guide Important Safety Instructions 1. Read these instructions – All the safety and operating instructions should be read before this product is operated. 2. Keep these instructions – The safety and operating instructions should be retained for future reference.
Page 3
INT-44HDX Installation Guide 26. When the apparatus is not in use or during its relocation, take care of the power cord and plugs; e.g. tie up the power cord with cable tie or similar. The tie must be free from sharp edges and the like that might cause abrasion of the power cord.
INT-44HDX Installation Guide Table of Contents Important Safety Instructions ����������������������������������������������������������������������������������������������������������������������������2 Product Overview ����������������������������������������������������������������������������������������������������������������������������������������������6 Package Contents ����������������������������������������������������������������������������������������������������������������������������������������������6 Front and Rear Panels ����������������������������������������������������������������������������������������������������������������������������������������7 Front Panel ���������������������������������������������������������������������������������������������������������������������������������������������������������� 7 Rear Panel ����������������������������������������������������������������������������������������������������������������������������������������������������������� 8 IR Remote ����������������������������������������������������������������������������������������������������������������������������������������������������������9 Control Routing Diagrams �������������������������������������������������������������������������������������������������������������������������������10 IR Routing ���������������������������������������������������������������������������������������������������������������������������������������������������������� 10 RS232 and TCP/IP to RS232 Routing ������������������������������������������������������������������������������������������������������������������...
Page 5
INT-44HDX Installation Guide Web Browser Control ���������������������������������������������������������������������������������������������������������������������������������������19 User Login ��������������������������������������������������������������������������������������������������������������������������������������������������������� 19 Matrix Routing - User ���������������������������������������������������������������������������������������������������������������������������������������� 19 Administrator Login ������������������������������������������������������������������������������������������������������������������������������������������ 20 Matrix Routing - Administrator ������������������������������������������������������������������������������������������������������������������������� 20 RS232 and TCP/IP Control ��������������������������������������������������������������������������������������������������������������������������������21 Routing Commands ������������������������������������������������������������������������������������������������������������������������������������������� 21 Preset Commands ��������������������������������������������������������������������������������������������������������������������������������������������� 22 Power Management �����������������������������������������������������������������������������������������������������������������������������������������...
Installation Guide Product Overview The Intelix INT-44HDX is a four input by four output HDBaseT/HDMI matrix switcher with HDCP 2.2 and UHD/30 video support. The matrix features advanced EDID and HDCP handling, including the ability to turn input HDCP compliance ON and OFF to ensure maximum functionality with a wide range of sources.
INT-44HDX Installation Guide Front and Rear Panels Front Panel INPUTS MENU EDID FIRMWARE CLEAR ENTER OUTPUTS Micro USB port for firmware updating Power indicator LED; IR receiver for matrix control via IR remote LCD screen Input select and LCD navigation buttons All button –...
INT-44HDX Installation Guide Rear Panel TCP/IP IR OUT ZONE 1 ZONE 2 ZONE 3 ZONE 4 IR IN IR IN IR IN IR IN IR EYE RS232 RS232 RS232 RS232 COAX COAX COAX COAX AUDIO AUDIO AUDIO AUDIO RS232 HDMI...
Installation Guide IR Remote The included IR remote performs all of the functions available on the front panel of the INT-44HDX. Please see page 17 for information on controlling the matrix from the front panel and the IR remote. The remote control requires two AAA batteries, which are included.
INT-44HDX Installation Guide Control Routing Diagrams IR Routing Out 1 IR In Out 4 IR In IR All In IR bridge 1 IR bridge 4 HDBT Out 1 HDBT Out 4 RS232 and TCP/IP to RS232 Routing 9600 baud TCP/IP In...
Apply power Mount the Matrix At least two inches of free air space is required on both sides of the INT-44HDX for proper side ventilation. Avoid mounting the INT-44HDX near a power amplifier or any other source of significant heat.
Using the included removable 3-pole terminal blocks, make a cable to interface between the audio device and the INT-44HDX as shown in the drawing above. Consult the documentation for the audio device to identify the left, left ground, right, and right ground audio signals.
Only use the included IR receiver or the IR-AC IR adapter cable (sold separately) with the INT-44HDX4. The IR adapter cables allow third party controllers to connect directly to the IR input ports of the INT-44HDX. If addition IR receivers are required, the DIGIB-EYE is a compatible substitute. Third party 12V DC IR components are not compatible with the INT-44HDX.
DIGI-HD60C-R or DIGI-HDX-R. To use the RS232 extension capabilities of the INT-44HDX, connect the TX, ground, and RX control signal wires to the removable 3-pole terminal block. Consult the manual of the control device(s) to determine which pins the TX/ RX signals are carried on.
Installation Guide Connect TCP/IP (Ethernet) Control The INT-44HDX may be controlled via Ethernet with a third party control system or through a web browser interface. Additionally, the INT-44HDX has an advanced RS232 control mechanism which will transmit RS232 commands through the HDBaseT output port to control remote devices with a simple command string.
Web Browser Control The INT-44HDX includes a web portal to allow control of the matrix via a standard web browser. The IP address is the same address that is used for TCP/IP control. See page 19 for detailed information regarding the web browser interface, including customization.
Basic Routing Setting a route using the front panel of the matrix will route the input signal to the selected output. To set a route using the front panel of the INT-44HDX: Press the desired input button (source). Press the desired output button (display).
Installation Guide IR Remote Operation The button functions on the IR remote are identical to the buttons on the front panel of the INT-44HDX. Only input and output numbers 1 through 4 are used on the remote. The Standby button will send the matrix to a low power state. Pressing the Standby button a second time will restore the INT-44HDX to full power.
Login INT-44HDX Open a web browser and go to the IP address of the INT-44HDX. The default IP address is 192.168.0.178. Type user in the Username field. Enter the password to gain control of the matrix. The default password is “user”.
Login INT-44HDX Open a web browser and go to the IP address of the INT-44HDX. The default IP address is 192.168.0.178. Type admin in the Username field. Enter the password to gain control of the matrix. The default password is “admin”.
INT-44HDX Installation Guide RS232 and TCP/IP Control RS232 Settings: 9600 baud, 8 Data bits, 1 Stop bit, Parity = None TCP/IP Settings: User defined IP address (default IP address: 192.168.0.178), port 8080 There is a period (.) at the end of each command. These characters must be present for the command to process correctly.
Clear preset 4 Power Management The INT-44HDX features two Standby modes. One Standby mode will leave power on to the HDBaseT ports. The other Standby mode will turn off power to the HDBaseT ports, which will also prevent passing RS232 commands via HDBaseT until the Power on command is transmitted to the INT-44HDX.
Advanced Front Panel and IR Remote Operation EDID Management The INT-44HDX has five built-in EDID settings for the inputs, but also allows copying the EDID information of an output device to the input of the matrix. Copy EDID from Output to Input To copy the EDID from output 3 to input 1: 1.
INT-44HDX Installation Guide System Query The INT-44HDX can provide basic system information through the front panel LCD. To check the current source going to an output, press and hold the output button for three seconds. To query the matrix status: 1.
Installation Guide IR Remote Operation The button functions on the IR remote are identical to the buttons on the front panel of the INT-44HDX. The EDID copy command sequences follow the same procedures as the front panel command sequences. The Standby button will send the matrix to a low power state. Pressing the Standby button a second time will restore the INT-44HDX to full power.
Input HDCP Settings HDCP is enabled on all inputs of the INT-44HDX. If the video output of the matrix is going to a video recorder, video converencing system, or other non-HDCP compliant device, the HDCP input compliance may need to be disabled to ensure the source does not encrypt the non-encrypted content.
INT-44HDX Installation Guide Web Browser Configuration When changes are made on a setup tab, the Save button must be pressed for the changes to take effect. User Tab The Users setup screen provides options to change the Administrator and User passwords. The front panel can also be locked to prevent tampering from this screen.
INT-44HDX Installation Guide HDCP and EDID Configuration Tab The Configuration setup screen has options to turn on and off the HDCP compliance flag for an input, select the audio input source for inputs 1 and 2, enable or disable the digital audio output, and copy the EDID from an output to an input.
Immediate RS232 Routing to HDBaseT The INT-44HDX has the logic to pass RS232 commands to remote devices through the TCP/IP or DE9 RS232 ports. The destination command string is embedded in a command which includes the destination HDBaseT port and baud rate.
Installation Guide Power On RS232 Routing to HDBaseT In addition to immediate transmission, the INT-44HDX can store commands to be broadcast when the matrix is powered on through the standby commands (PWON., STANBY., and PWOFF.). The format of the RS232 routing string is: /+<Y>/<B>:<$>. (The period at the end of the string is required.) <Y>...
INT-44HDX Installation Guide RS232 and TCP/IP System Query Routing Queries Description Command Response Statusy. x-> y Output y routing status (only 1 digit) Status. 1-> 1 Routing status of all outputs. 2-> 2 3-> 3 4-> 4 Signal Status Queries...
INT-44HDX Installation Guide Matrix Status Queries Description Command Response /*Type; INT-44HDX Get model number /^Version; V1.0.0 Check the software version %9961. Query system lock state System Locked! or System Unlock! %9962. Query standby state PWON STANDBY PWOFF %9964. IP:192.168.0.178 Query the IP address...
INT-44HDX Installation Guide Troubleshooting Matrix does not power on Verify power outlet is active. » Verify continuity in power cable. » Cannot view 4K (UHD) content Copy EDID from output to input. » Verify display is 4K (UHD) compatible. »...
INT-44HDX Installation Guide Technical Specifications Input/Output Connections HDMI Inputs Four (4) HDMI Type A Receptacle IR Outputs Four (4) 3.5mm TRS HDMI Outputs (Outputs 1 and 2 only) Two (2) HDMI Type A Receptacle Four (4) 8P8C Port (Shielded RJ45 Female)