  • Page 1 FLX-88 Installation and Operation Guide Rev 150126 8001 Terrace Ave Phone: 608-831-0880 Suite 201 Toll-Free: 866-462-8649 Middleton, WI 53562 Fax: 608-831-1833...
  • Page 2 FLX-88 Installation Guide...
  • Page 3: Important Safety Instructions

    Do not block the air ventilation openings. Only mount the equipment per Intelix’s instructions.  Use only with the cart, stand, table, or rack specified by Intelix or sold with the equipment. When/if a cart is used, use caution when ...
  • Page 4: Table Of Contents

    FLX-88 Installation Guide Table of Contents Overview ............................... 6 Package Contents ..........................6 Front Panel ............................7 Rear Panel ............................8 IR Remote ............................8 Input Cards ..............................9 Analog Video (FLX-RI4) ........................9 DVI (FLX-DI4) ............................ 9 HDBaseT (FLX-BI4) ..........................9 HDMI (FLX-HI4A) ..........................
  • Page 5 Cannot view 3D content ........................ 29 Cannot hear surround sound audio ....................29 No video from HDBaseT input or output ..................29 Technical Specifications ..........................30 FLX-88 Chassis ..........................30 FLX-BI4 ............................31 FLX-HI4A ............................32 FLX-RI4 ............................33 FLX-DI4 ............................34 FLX-BO4A ............................
  • Page 6: Overview

    FLX-88 Installation Guide Overview The Intelix FLX-88 is a modular eight input by eight output video matrix switcher. Each modular input or output card supports up to four device connections. In addition to front panel control, the FLX-88 can be controlled via IR, RS232, or TCP/IP connections.
  • Page 7: Front Panel

    FLX-88 Installation Guide Front Panel Input Menu Power LED/ IR Buttons (Top) Receiver Rack LCD Status Output Menu Handle Display Buttons (Bottom) Power LED – Indicates the matrix has proper input power. IR Receiver – For use with the included IR remote.
  • Page 8: Rear Panel

    AC Input – Standard IEC C14 inlet. Redundant power inlet – connect to [2] separate circuits, if the first circuit loses power, the matrix will switch automatically to the other circuit. IR Remote The included IR remote performs all of the functions available on the front panel of the FLX-88.
  • Page 9: Input Cards

    FLX-88 Installation Guide Input Cards The modular input cards are keyed on the right side to line up with the output cards and ensure they are installed correctly in the matrix. Analog Video (FLX-RI4) The HD15 inputs on the FLX-RI4 scale and convert a wide range of analog video signals to HD video resolutions, which can be routed to any available output.
  • Page 10: Hdmi (Flx-Hi4A)

    FLX-88 Installation Guide HDMI (FLX-HI4A) The FLX-HI4 HDMI inputs can be routed to any available outputs. The HDMI inputs can accept video signals up to 1920x1200, including 3D and 48-bit Deep Color at 1080p. Additionally, audio signals from stereo up to 7.1 audio streams will pass through the matrix to supported outputs.
  • Page 11: Output Cards

    FLX-88 Installation Guide Output Cards The modular output cards are keyed on the left side to line up with the input cards and ensure they are installed correctly in the matrix. DVI (FLX-DO4) The FLX-DO4 DVI-D outputs are HDMI and HDCP compliant and support CEC and DDC standards. Each output is a single link DVI-D connection that can support video resolutions up to 1920x1200.
  • Page 12: Long Reach Hdbaset (Flx-Bo4A-Xl)

    3.5mm jacks. The FLX-BO4A-XL features advanced EDID handling features that ensure video and audio compatibility, such as full copy and hybrid copy functions. The DIGI-HDXL series extenders are only compatible with Intelix XL-series HDBaseT product offerings. An HDBaseT link will not be established with other HDBaseT products.
  • Page 13: Installation Instructions

    Rack Mounting Instructions The FLX-88 requires two rack units (2 RU) of space. At least 2 inches of free air space is required on both sides of the FLX-88 for proper side ventilation. Avoid mounting the FLX-88 near a power amplifier or any other source of significant heat.
  • Page 14: Flx-Bi4 And Flx-Bo4A Wiring

    FLX-88 Installation Guide 3. Slide the I/O card between the guide rails until it is firmly seated. 4. Secure the I/O card by tightening the thumb screws. 5. Connect the appropriate cabling to the I/O card. 6. Power on the matrix.
  • Page 15: Flx-Ri4 Wiring

    FLX-88 Installation Guide To use the IR extension capabilities of the FLX-BI4, the DIGIB-EYE (wideband IR receiver) and DIGIB-EMT (wideband IR emitter) will need to be connected to the appropriate IR ports. These parts are not included with the HDBaseT I/O cards.
  • Page 16 FLX-88 Installation Guide For component video, S-video, and composite video, a VGA to breakout cable is recommended. The FLX- RI4 comes with two FLX-RBOCA (component video breakout cable) and two FLX-RBOCB (composite and S-video breakout cable) cables. See FLX-RI4 Specific Commands on page 27 to define the operation of the inputs.
  • Page 17: Edid Management

    FLX-88 Installation Guide EDID Management The stock EDID for the inputs of the FLX-88 is 1280x1024 (computer video input) and 1080p with stereo audio (consumer video input). In order to change the EDID information for an input, the EDID copy command will need to be sent to the matrix via RS232 or TCP/IP.
  • Page 18: Front Panel And Ir Remote Operation

    2. Press THROUGH. IR Remote Operation The buttons on the IR remote are identical to the buttons on the front panel of the FLX-88. The IR routing commands are identical to the front panel commands. See Page 8 for the button layout of the IR remote.
  • Page 19: Third Party Control Setup

    Configuring the TCP/IP port is done via a web browser interface. A crossover cable is required for the initial setup. The default IP address is printed on a sticker on the side of the FLX-88. 1. Configure the computer to use the same network prefix as the IP address assigned to the matrix.
  • Page 20 6. Press the LOGIN button. Pressing the Enter key will give a bad password error. 7. Click the System Info button to change the IP address. 8. Changing the dropdown option from Static to DHCP will allow the FLX-88 to automatically obtain an IP address from a DHCP server on the network.
  • Page 21: Access The Web Browser With Defined Ip Address (Firmware V1.6.4 And Below)

    Additional Options in Web Browser (Firmware v1.6.4 and below) 1. Serial Info – Adjusts TCP/IP specific settings, including the default port (4001). a. Changing the baud rate settings has no effect on the RS232 port of the FLX-88. b. The baud rate setting must remain at 9600.
  • Page 22: Ip Address Setup Via Web Browser (Firmware V1.6.5 And Above)

    Configuring the TCP/IP port is done via a web browser interface. A crossover cable is required for the initial setup. The default IP address is printed on a sticker on the side of the FLX-88. 1. Configure the computer to use the same network prefix as the IP address assigned to the matrix.
  • Page 23: Access The Web Browser With Defined Ip Address (Firmware V1.6.5 And Above)

    FLX-88 Installation Guide 8. Changing the WAN Connection Type dropdown option from Static to DHCP will allow the FLX-88 to automatically obtain an IP address from a DHCP server on the network. 9. For a static IP, enter the IP address, Gateway, and DNS Server information provided by your Network Administrator.
  • Page 24: Additional Options In Web Browser (Firmware V1.6.5 And Above)

    FLX-88 Installation Guide Additional Options in Web Browser (Firmware v1.6.5 and above) 1. web-server: Status – Displays system up time and matrix network settings in Internet Configurations table. 2. web-server: Statistic – Displays network communication statistics. 3. web-server: Management – Allows changing of Administrator account name (default is admin) and password (default is admin).
  • Page 25: Rs232 And Tcp/Ip Commands

    FLX-88 Installation Guide RS232 and TCP/IP Commands RS232 Settings: 9600 baud, 8 Data bits, 1 Stop bit, Parity = None TCP/IP Settings: User defined IP address, port 4001 There is either a period (.) or a semicolon (;) at the end of each command. These characters must be present for the command to process correctly.
  • Page 26: Preset Commands

    FLX-88 Installation Guide Preset Commands Description Command Response Savex. Save to Fx<CR><LF> Save the current routing as a preset. Values range from 0 through 9 Recallx. Recall From Recall preset x Fx<CR><LF> Clearx. Clear preset x Examples: Save4. Save the current routing as preset 4.
  • Page 27: Hdcp Commands

    FLX-88 Installation Guide HDCP Commands Description Command Response /%I/xx:0. /%I/xx:0.<CR><LF> Turn HDCP Compliance off for input xx /%I/xx:1. /%I/xx:1.<CR><LF> Turn HDCP Compliance on for input xx Example: /%I/04:0. Turn HDCP Compliance off for input 4 FLX-RI4 Specific Commands (Firmware version 1.6.1 and below) The input number values are dependent upon which slot the FLX-RI4 is inserted.
  • Page 28: Flx-Ri4 Specific Commands (Firmware Version 1.6.4 And Above)

    FLX-88 Installation Guide FLX-RI4 Specific Commands (Firmware version 1.6.4 and above) The input number values are dependent upon which slot the FLX-RI4 is inserted. If the input card is in the first input card slot, the input number values range from 01 through 04. If the input card is in the second input card slot, the input number values range from 05 through 08.
  • Page 29: Troubleshooting

    FLX-88 Installation Guide Troubleshooting Matrix does not power on Verify power outlet is active. Verify continuity in power cable. Cannot view 3D content Copy EDID from output to input. Verify display is 3D compatible. Verify source device can output 3D content.
  • Page 30: Technical Specifications

    ESD Protection 15kV Regulatory CE, RoHS Other Warranty 2 years Diagnostic Indicators LCD output status and power LED Included Accessories Installation Guide, IR Remote, RS232 Cable, Power Cable, Modular Metal Blank (4 ea), Rubber Feet (4 ea) and Intelix Pocket Screwdriver.
  • Page 31: Flx-Bi4

    -10° to +60° C (+14° to +140° F) Storage Humidity 20% to 90%, Non-condensing Other Warranty 2 years Matrix Switcher Compatibility FLX-8X8A, FLX-88, FLX-1616, FLX-3232 HDBaseT Transmitter (A/V and Control) DIGI-HD60C-S, DIGI-HDE-S, DIGI-P123, DIGI-P52, ASW-WP HDBaseT Transmitter (A/V Only) DIGI-HD70-S Infrared (IR) Emitter DIGIB-EMT...
  • Page 32: Flx-Hi4A

    FLX-88 Installation Guide FLX-HI4A Technical Specifications I/O Connections HDMI Input Four (4) HDMI Type A Receptacle Connector Analog Audio In Four (4) 3 pole Euroblock Connectors Supported Audio and Video Maximum Video Compatibility Deep Color 48/36/30/24 Bit at 1080p, 3D...
  • Page 33: Flx-Ri4

    40 mm (15.75 in.) Male HD15 to three (3) Female RCA Connectors (Red, Green, Blue) FLX-RBOCB (2 ea) 40 mm (15.75 in.) Male HD15 to one (1) Female RCA Connector (Yellow) and one (1) Female S-Video Connector Other Warranty 2 years HDMI Matrix Switcher Compatibility FLX-8X8A, FLX-88, FLX-1616, FLX-3232...
  • Page 34: Flx-Di4

    0° to +40° C (+32° to +104° F) Operating Humidity 20% to 90%, Non-condensing Storage Temperature -10° to +60° C (+14° to +140° F) Storage Humidity 20% to 90%, Non-condensing Other Warranty 2 years Matrix Switcher Compatibility FLX-8X8A, FLX-88, FLX-1616, FLX-3232...
  • Page 35: Flx-Bo4A

    FLX-88 Installation Guide FLX-BO4A Technical Specifications I/O Connections HDBaseT Port Four (4) 8P8C port (Shielded RJ45) Analog Audio Out Four (4) 3.5 mm TRS RS232 Four (4) 3 pole Euroblock Connectors Supported Audio, Video and Control Maximum Video Compatibility at 70 m...
  • Page 36: Flx-Ho4A

    FLX-88 Installation Guide FLX-HO4A Technical Specifications I/O Connections HDMI Input Four (4) HDMI Type A Receptacle Connector Analog Audio Out Four (4) 3 pole Euroblock Connectors Supported Video Maximum Video Compatibility Deep Color 48/36/30/24 Bit at 1080p, 3D Video Compliance...
  • Page 37: Flx-Do4

    0° to +40° C (+32° to +104° F) Operating Humidity 20% to 90%, Non-condensing Storage Temperature -10° to +60° C (+14° to +140° F) Storage Humidity 20% to 90%, Non-condensing Other Warranty 2 years Matrix Switcher Compatibility FLX-8X8A, FLX-88, FLX-1616, FLX-3232...
  • Page 38: Flx-Bo4A-Xl

    FLX-88 Installation Guide FLX-BO4A-XL Technical Specifications I/O Connections HDBaseT Port Four (4) 8P8C port (Shielded RJ45) Analog Audio Out Four (4) 3.5 mm TRS RS232 Four (4) 3 pole Euroblock Connectors Supported Audio, Video and Control Maximum Video Compatibility at 150 m...
  • Page 39: Digib-Emt

    FLX-88 Installation Guide DIGIB-EMT Technical Specifications Signal Characteristics Wide-Band Infrared (IR) 30 KHz to 56 KHz at 5V DC reference Physical Characteristics Material, Emitter Housing Deep red translucent plastic Dimensions, Emitter Housing 6 mm x 9.5 mm x 15 mm (0.24 in. x 0.37 in. x 0.59 in.) Cable Length 2 m (6.56 ft)
  • Page 40 FLX-88 Installation Guide Thank you for your purchase. Please contact us with your questions and comments. Intelix 8001 Terrace Ave, Ste 201 Middleton, WI 53562 Phone: 608-831-0880 Toll Free: 866-462-8649 Fax: 608-831-1833 www.intelix.com supportlibav@libav.com...