operating
instructions

COPY OF LIGHTING PLATE INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING
This appliance must be installed in accordance
with the current AS/NZS 5601-2013
WARNING: If you do not follow these
instructions exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life. Improper
installation, adjustment, alteration, service
or maintenance can cause injury or property
damage. Refer to the owner's information
manual provided with this appliance. For
assistance or additional information consult
a qualified installer, service agency or gas
supplier.
A) BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the
floor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance
- Do not touch any electric switch, do not use
any phone in your building
- Immediately call your gas supplier from a
neighbors phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call the fire
department.
B) Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of
the control system and any gas control which has
been under water.
This appliance needs fresh air for safe operation and
must be installed so there are provisions for adequate
combustion and ventilation air.
CAUTION: Hot while in operation. Do not
touch. Severe Burns may result. Due to
high surface temperatures keep children,
clothing and furniture, gasoline and other
liquids having flammable vapors away. Keep
burner and control compartment clean.
See installation and operating instructions
accompanying appliance.
LIGHTING INSTRUCTIONS
STOP! Read the safety information above on this
label.
1)
Plug the power cord into a power outlet.
2)
Press and release the ON/OFF button once to
start the unit.
*
ON/OFF function may be controlled by either
Remote Wall Mount Control or ON/OFF control
on the Unit.
3)
After approximately 3 seconds the spark
ignition system will spark for 25 seconds to
light the main burner.
4)
If the main burner does not light, check the
gas and reset the unit.
TO TURN OFF GAS APPLIANCE
1)
Press the ON/OFF button once.
2)
Turn off all electric power to the unit if service
is to be performed.
DO NOT REMOVE THIS
INSTRUCTION PLATE
Part #: 919-130a
Colours:
Black on Grey, except for parts in RED
Size:
W 2.74" x H 11.94"
Mar. 12/12: created draft
Sept. 21/15: Rev. A - changed standard
44
NORMAL OPERATING
SOUNDS OF
GAS APPLIANCES
It is possible that you will hear some sounds from
your gas appliance. This is perfectly normal due to
the fact that there are various gauges and types
of steel used within your appliance. Listed below
are some examples. All are normal operating
sounds and should not be considered as defects
in your appliance.
Blower:
Regency gas appliances use high tech blowers
to push heated air farther into the room. It is not
unusual for the fan to make a "whirring" sound
when ON. This sound will increase or decrease
in volume depending on the speed setting of
your fan speed control.
Burner Tray:
The burner tray is positioned directly under the
burner tube(s) and logs and is made of a differ-
ent gauge material from the rest of the firebox
and body. Therefore, the varying thicknesses of
steel will expand and contract at slightly different
rates which can cause "ticking" and "cracking"
sounds. You should also be aware that as there
are temperature changes within the unit these
sounds will likely re-occur. Again, this is normal
for steel fireboxes.
Gas Control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will
expand and contract at different rates resulting
in some "cracking" and "ticking" sounds will be
heard throughout the cycling process.
WARNING:
DO NOT SPRAY AEROSOLS IN THE VICINITY OF
THIS APPLIANCE WHILE IN OPERATION.
919-130a
Appliances incorporating a live fuel effect (designed to oper-
"
ate with blue flames with slight yellow tips) may exhibit slight
carbon deposition."

RESETTING THE UNIT

If the appliance goes to 'lockout', the system
will have to be reset by depressing the reset
button - located on the right side of the unit
by outer door frame with the unit in the "ON
POSITION" (fan running).
*Important: Wait at least 5 min for any
unburned gas to clear before resetting the
appliance.
1) Turn on the unit. Fan should be heard.
2) Press and hold down the reset button for at
least 5-10 seconds.
NOTE: If nothing happens, Repeat Step 1
-one more time.
3) The pilot sparks can be heard and seen at
the back. It will take approximately 2 to 3
seconds for the flame to be lit.
NOTE: Wait 5 minutes between reset attempts.
NOTE: If unit fails to light after 25 seconds;
wait 5 min, then manually reset using
black button on the right hand side
below glass frame.