Power Up Procedure; Security Network - Philio PSP05 Quick Start Manual

Motion sensor
Table of Contents

Advertisement

Notification Type: Home Security (0x07)
Event: Motion Detection, Unknown Location (0x08)
Sensor Binary Report (V2)
Sensor Type: Motion (0x0C)
Sensor Value: 0xFF
* Tamper Report:
When tamper key are pressed over 5 seconds. The device will into the
alarm state. In that state, if the tamper key is released, the device will
unsolicited to send the report to the nodes in the group 1.
Notification Report (V4)
Notification Type: Home Security (0x07)
Event: Tampering. Product covering removed (0x03)
Sensor Binary Report (V2)
Sensor Type: Tamper (0x08)
Sensor Value: 0xFF
* Timing Report:
Beside the event triggered could report message, the device also
support the timing unsolicited report of the status.
Battery level report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 10.
Low battery report: When the battery level is too low, every 30
minutes will report once.
Notice: The configuration NO. 10 could be setting to zero to disable
the auto report. And the configuration NO. 20 could change the tick
interval, the default value is 30, if setting to 1, that means the
minimum auto report interval will be one minute. And please notice if
setting this value to zero, that means disable all of the timing report
except the low battery detection.

Power Up Procedure

* Battery Power Check
When the device power up, the device will detect the power level of the
battery immediately. If the power level is too low, the LED will continue
flash about 5 seconds. Please change another new battery.
* PIR Warm Up
When the device power on, the PIR need to warm up before the
operation. The warm up time about 1 minute, the LED will flash in
every 2 seconds. After finish the procedure the LED will light ON three
times.
* NWI
When the device power on, the device will check is it already adding to
the network? If doesn't, it will auto start the NWI mode. The LED will
flash in every second and continue 30 seconds. Until timeout or the
device successful to inclusion by controller. The use can presses button
once to abort the NWI mode.
* Wake
When the device power on, the device will wake about 20 seconds. In
this duration, the controller can communicate with the device. Normally
the device is always sleeping to save the battery energy.

Security Network

The device support the security function. When the device included
with a security controller, the device will auto switch to the security
mode. In the security mode, the follow commands need using Security
CC wrapped to communicate, otherwise it will not response.
Note: A "Security Enabled Z-Wave Controller" must be used in order to
fully utilize this function.
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psp05-aPsp05-bPsp05-cPsp05-d

Table of Contents