Power Up Procedure; Function Dip Switch; Operation Mode - Philio PSM02 Manual

Slim multi-sensor
Table of Contents

Advertisement

nodes in the group 1.
The device will measure the temperature in every 64 seconds. And if
the temperature is over 140 degree Fahrenheit (60 degree Celsius), the
device also report in each measurement.
* Illumination Report:
When the PIR motion detected or the door/window state changed, the
device will unsolicited to send the "Sensor Multilevel Report" to the
nodes in the group 1.
Sensor Type: Luminance (0x03)
Note: To disable this functionality by setting the configuration setting
N0.5, the bit4 of the value to 1.
* Timing Report:
Beside the event triggered could report message, the device also
support the timing unsolicited report of the status.
Battery level report: Every 6 hours report once in default.
It could be changed by configuration setting NO. 10.
Low battery report: When the battery level is too low, every 30
minutes will report once.
Door/window state report: Every 6 hours report once in default.
It could be changed by configuration setting NO. 11.
Illumination level report: Every 6 hours report once in default.
It could be changed by configuration setting NO. 12.
Temperature report: Every 6 hours report once in default.
It could be changed by configuration setting NO. 13.

Power Up Procedure

* Battery Power Check
When the power up, the device will detect the power level of the
battery immediately. If the power level is too low, the LED will continue
flash about 5 seconds. Please change another new battery.
* PIR Warm Up
When the power on, the PIR need to warm up before operation. The
warm up time about 1 minute, the LED will flash in every 2 seconds.
After finish the procedure the LED will light ON three times.
* NWI
When the power on, the device will check is it already adding to the
network? If doesn't, it will auto start the NWI mode. The LED will flash
in every second and continue 30 seconds. Until timeout or the device
successful to inclusion by controller.
* Wake
When the power on, the device will wake about 20 seconds. In this
duration, the controller can communicate with the device. Normally the
device is always sleeping to save the battery energy.

Function DIP Switch

There is one function DIP switch in front of the device.
Remove the front cover in the right top of the PCB, and also has mark
"M1" and "M2" for two switch.
M1 M2
ON ON Test Mode.
ON OFF Security Mode.
OFF ON Home Automation Mode.
Program Mode. According to the configuration setting
OFF OFF
NO. 5 to set the operation mode.

Operation Mode

There are three operation modes of the device. The user can choosing
the suitable mode for application.
3
Description

Advertisement

Table of Contents
loading

Table of Contents