Philio PAT02-A-NS Manual

Philio PAT02-A-NS Manual

Flood multisensor

Advertisement

Quick Links

Flood Multisensor PAT02-A/B/C-NS
The flood multisensor PAT02 has flood, temperature and humidity, 3
sensors function in one, based on Z-Wave
It is the Z-Wave
TM
plus product, it support the OTA... Those newest
features of the Z-Wave
TM
communication protocol designed for home automation, specifically to
remotely control applications in residential and light commercial
environments. The technology uses a low-power RF radio embedded or
retrofitted into home electronics devices and systems, such as lighting,
home access control, entertainment systems and household appliances.
This product can be included and operated in any Z-Wave
with other Z-Wave
TM
certified devices from other manufacturers and/or
other applications. All non-battery operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network.
TM
technology.
technology. Z-Wave
TM
is a wireless
The device adopt the Z-Wave
network system is all made by Z-Wave
network system will have the advantages as below.
Concurrent multi-channel support reduces external interference.
Better RF range, improve about 10 meters in indoor.
Support 100 Kbps transmit speed, speed up communication.
Function Compare A/B/C
PAT02-A-NS
PAT02-B-NS
PAT02-C-NS
Add to/Remove from Z-Wave
There are one tamper keys in the back side of the device, It can add,
remove, reset or association from the Z-Wave
In the first time, add the device into the Z-Wave
sure the primary controller is in the add mode. And then power on the
device, just take out the insulation Mylar in the back side of the device.
The device will auto start the NWI (Network Wide Inclusion) mode. And
it should be included in 5 seconds. You will see the LED light ON one
second.
TM
network
Notice: Including a node ID allocated by Z-Wave
"Add" or "Inclusion". Excluding a node ID allocated by Z-Wave
Controller means "Remove" or "Exclusion".
1
TM
500 series chip, when your Z-Wave
TM
500 series devices. The
Flood
Temperature
V
V
V
V
TM
Network
TM
network.
TM
TM
TM
Humidity
V
V
network. First, make
Controller means
TM

Advertisement

Table of Contents
loading

Summary of Contents for Philio PAT02-A-NS

  • Page 1 Support 100 Kbps transmit speed, speed up communication. • Function Compare A/B/C Flood Temperature Humidity PAT02-A-NS PAT02-B-NS PAT02-C-NS Add to/Remove from Z-Wave Network The flood multisensor PAT02 has flood, temperature and humidity, 3 There are one tamper keys in the back side of the device, It can add, sensors function in one, based on Z-Wave technology.
  • Page 2: Function Description

    Function Description from Z-Wave Controller. 1. Have Z-Wave Controller entered inclusion mode. Notice 1: Always RESET a Z-Wave device before trying to add it to a 2. Pressing the tamper key three times within 1.5 Z-Wave network seconds to enter the inclusion mode. 3.
  • Page 3 Sensor Type: Temperature (0x01) Note: To disable send temperature report after the flood triggered, Sensor Binary Report (V2) please setting the configuration N0.5 bit5 to 1. Sensor Type: Water (0x06) Sensor Value: 0xFF *** Temperature differential report *** This function default is enabled, to disable this function by setting the configuration NO.21 to 0.
  • Page 4: Power Up Procedure

    It could be changed by setting the configuration NO. 10. Low battery report: When the battery level is too low, every 30 * Wake • minutes will report once. When the device power on, the device will wake about 20 seconds. In Temperature report: Every 6 hours report once in default.
  • Page 5: Battery Installation

    Battery Installation When the device report the low battery message. The user should replace the battery to new one. The battery type is CR123A, 3.0V. The way to open the front cover please press the top position, to release the cover. Replace the new battery and install the cover back.
  • Page 6: Z-Wave Configuration Settings

    “RESET” procedure. * The reserve bit or not supported bit is allowed any value, but no effect. Name Description Def. A B C Valid Setting the BASIC command value. Basic Set    When the flood trigger off(0x00), send OFF Level the BASIC CC to the group 2.
  • Page 7 Name Description Name Description Def. A B C Def. A B C Valid Valid    Bit4: Reserve. The default value is 12. The tick time Time can setting by the configuration No.20.    Bit5: Reserve. Bit6: Disable the humidity report after ...
  • Page 8: Z-Wave Supported Command Class

    Name Description Def. A B C Valid And when the temperature is over 140 degree Fahrenheit, it will continue report. Specifications    Power by CR123A lithium battery. The humidity differential to report. Signal (Frequency): Humidity 0 means turn off this function. 868.40 MHz, 869.85 MHz(EU), Differential The unit is percentage.
  • Page 9: Fcc Interference Statement

    FCC Interference Statement Warning This equipment has been tested and found to comply with the limits for Do not dispose of electrical appliances as unsorted municipal waste, a Class B digital device, pursuant to Part 15 of the FCC Rules. These use separate collection facilities.