COMMAND_CLASS_BATTERY
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_WAKE_UP_V2

Operation Mode

There are two modes "Test" and "Normal". "Test Mode" is for the user
test the sensor function when installation."Normal Mode" is for the
normal operation.
Operation Mode can be switched by pressing button or tamper key two
times. LED can indicate which mode it is. Lighting on one second
means entering test mode, flashing once means entering normal mode.
When the event triggered, normally the LED won't indicated, unless the
battery is in the low level, the LED will flash once. But in the "Test
Mode" the LED also will light ON one second.
When the event triggered, the device will report the messages to the
nodes in the group 1. The messages also include the battery level. The
user can switch the report by setting the configuration NO. 7 bit6
(battery).
When the event triggered, the device will emit the signal to turn ON the
lighting equipment, those nodes are in the group 2. And delay a while
to turn OFF the lighting equipment. The delay time is setting by the
configuration NO. 9.
The PIR motion re-detected interval, in the "Test Mode" fixed to 6
seconds. In the "Normal Mode", it according to the setting of the
configuration NO. 8.

Choosing a Suitable Location

1. The recommended mounting height is 160cm
2. Don't let the device facing the window or the sunlight.
3. Don't let the device facing the source of heat. For instance the
heater or the air-condition.

Battery Installation

When the device reports the low battery message, users should
replace the battery. The battery type is CR123A, 3.0V.