Power Up Procedure; Over The Air (Ota) Firmware Update - Philio PAT15 Quick Start Manual

Flood water sensor
Table of Contents

Advertisement

And after the flood trigger clear, the device will unsolicited to send the
report to the nodes in the group 1.
Notification Report (V8)
Notification Type: Water Alarm (0x05)
Event: 0x00
* Tamper Report:
The tamper key pressed over 5 seconds. The device will into the alarm
state. In that state, if the tamper key be released, the device will
unsolicited to send the report to the nodes in the group 1.
Notification Report (V8)
Notification Type: Home Security (0x07)
Event: Tampering. Product covering removed (0x03)
* Timing Report:
Beside the event triggered could report message, the device also
support the timing unsolicited report of the status.
Battery level report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 1.
Low battery report: When the battery level is too low, every 30
minutes will report once.
Flood state report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 5.
Notice : The configuration NO. 1 could change the tick interval, the
default value is 60, if setting to 1, that means the minimum auto report
interval will be one minute.

Power Up Procedure

* Battery Power Check
When the device power up, the device will detect the power level of the
battery immediately. If the power level is too low, the LED will flash
three times. Please change another new battery.
* Wake
When the device power on, the device will wake about 20 seconds. In
this duration, the controller can communicate with the device. Normally
the device is always sleeping to save the battery energy.

Over The Air (OTA) Firmware Update

The device support the Z-Wave firmware update via OTA.
Let the controller into the firmware update mode, and then press the
tamper key once to start the update.
After finish the firmware download, please don't remove the
battery , otherwise it will cause the firmware broken, and the device
will no function.
After the LED stop flash, it is recommended that the user power up the
device. Caution: After remove the battery, please wait about 30
seconds, and then re-install the battery.