Slim Multi-Sensor PSM02
The slim multi-sensor PSM02 has PIR, door/window, temperature and
illumination, 4 sensors function in one, based on Z-Wave
Z-Wave
TM
is a wireless communication protocol designed for home
automation, specifically to remotely control applications in residential
and light commercial environments. The technology uses a low-power
RF radio embedded or retrofitted into home electronics devices and
systems, such as lighting, home access control, entertainment systems
and household appliances.
This device is one component of the Z-Wave
designed to work with all other Z-Wave
control network. The device adopt the Z-Wave
your Z-Wave
TM
network system is all made by Z-Wave
devices. The network system will have the advantages as below.
Concurrent multi-channel support reduces external interference.
Better RF range, improve about 10 meters in indoor.
Support 100 Kbps transmit speed, speed up communication.
TM
technology.
TM
sensor system and is
TM
enabled devices in a home
TM
400 series chip, when
TM
400 series
Adding to Z-Wave
TM
There are two tamper keys in the device, one is in the back side,
another is in the front side. They have the same function. Both of them
can inclusion, exclusion, reset or association from Z-Wave
In the first time, add the device into the Z-Wave
sure the primary controller is in the inclusion mode. And then power on
the device, just take out the insulation Mylar in the back side of the
device. The device will auto start the NWI (Network Wide Inclusion)
mode. And it should be included in 5 seconds. You will see the LED
light ON one second.
Function
Description
1. Have Z-Wave
2. Pressing tamper key three times within 1.5 seconds
will enter inclusion mode.
Inclusion
3. After inclusion successful, the device will wake to
receive the setting command from Z-Wave
Controller about 20 seconds.
1. Have Z-Wave
2. Pressing tamper key three times within 1.5 seconds
Exclusion
will enter exclusion mode.
Node ID has been excluded.
1. Pressing tamper key four times within 1.5 seconds
and do not release the tamper key in the 4
pressed, and the LED will turn ON.
2. After 3 seconds the LED will turn OFF, after that
within 2 seconds, release the tamper key. If
Reset
successful, the LED will light ON one second.
Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to
factory default.
1
Network
TM
network. First, make
TM
Controller entered inclusion mode.
TM
Controller entered exclusion mode.
TM
network.
TM
th

Advertisement

Table of Contents
loading

Summary of Contents for Philio PSM02

  • Page 1 Description 1. Have Z-Wave Controller entered inclusion mode. 2. Pressing tamper key three times within 1.5 seconds The slim multi-sensor PSM02 has PIR, door/window, temperature and will enter inclusion mode. illumination, 4 sensors function in one, based on Z-Wave technology.
  • Page 2 Z-Wave Message Report 1. Have Z-Wave Controller entered association mode. * Motion Report: 2. Pressing tamper key three times within 1.5 seconds When the PIR motion detected, the device will unsolicited to send the will enter association mode. Association Note: The device support 2 groups. The group 1 is for “Sensor Binary Report”...
  • Page 3: Power Up Procedure

    nodes in the group 1. * PIR Warm Up The device will measure the temperature in every 64 seconds. And if When the power on, the PIR need to warm up before operation. The the temperature is over 140 degree Fahrenheit (60 degree Celsius), the warm up time about 1 minute, the LED will flash in every 2 seconds.
  • Page 4 There are three modes “Test”, “Home Automation” and “Security”. “Test Mode” is for the user test the sensor function when installation. “Home Automation Mode” focus in automatic to control the lighting equipment. For convenience and save energy. “Security Mode” focus in surveillance, warning. When the event triggered, normally the LED won't indicated, unless the battery is in the low level, the LED will flash once.
  • Page 6: Battery Installation

    Battery Installation When the device report the low battery message. The user should replace the battery to new one. The way to open the front cover please follow below steps. 1. Using a tool like (1) to press 1-1 till hear a click sound 2.
  • Page 7: Installation

    Installation After finish the test and decide to fix, then you can remove tape A, and mounting the sensor by using tape B. This will close the tamper key 1. In the first time, add the device into the Z-Wave network.
  • Page 8 0 means disable the PIR motion. 0: Fahrenheit , 1: Celsius 1 means the lowest sensitivity, Bit4: Disable illumination report after 99 means the highest sensitivity. event triggered. High sensitivity means can detected long Bit5: Disable temperature report after distance, but if there is more noise signal event triggered.
  • Page 9: Z-Wave Supported Command Class

    Z-Wave Supported Command Class time. 8 seconds per tick, and minimum time is 24 seconds, default tick is 3 (24 COMMAND_CLASS_CONFIGURATION seconds). COMMAND_CLASS_VERSION Setting the suitable value to prevent COMMAND_CLASS_SENSOR_BINARY_V2 received the trigger signal too frequency. COMMAND_CLASS_ASSOCIATION_V2 Also can save the battery energy. COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 Notice: If this value bigger than the COMMAND_CLASS_WAKE_UP_V2...
  • Page 10: Limited Warranty

    This This device complies with Part 15 of the FCC Rules. Operation is subject warranty extends only to wholesale customers who buy through Philio to the following two conditions:...