The PAT05 multi-sensor is a device that allows you to check the air quality in your
home. The PAT05 Multi-sensor is easy to use and very convenient for your home. Just
set the sensor on the wall of the rooms you would like to control, and you are ready to
go. Moreover, the PAT05 can be integrated to other Z-Wave certified devices, and
controlled with Philio app "Home Mate 2." You can now protect your family and make
sure there are no gas leaks that can harm those you love the most. Set up your
PAT05 to send regular notifications and take control even when not at home.
This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-
Wave Plus messages to communicate to other security enabled Z-Wave Plus
products. Z-Wave
TM
enabled devices displaying the Z-Wave
with it regardless of the manufacturer, and ours can also be used in other
manufacturer's Z-Wave
TM
enabled networks.
The product supports Over The Air(OTA) feature for the products firmware upgrade.
This product can be included and operated in any Z-Wave
Wave
battery operated nodes within the network will act as repeaters regardless of vendor
to increase reliability of the network.
The device adopt the Z-Wave
is all made by Z-Wave
advantages as below.
Notice:
Once you have completed the setup process, Please allow for a 7-Day settling period
for the sensors to adjust to their new environment and to observe a typical cycle of air
quality, based on your activity within a 1 week period.
Add to/Remove from Z-Wave
There are one tamper keys in the device, in the back side. Can be add, remove, reset
or association from Z-WaveTM network.
The table below lists an operation summary of basic Z-Wave functions. Please refer
to the instructions for your Z-WaveTM Certificated Primary Controller to access the
Setup function, and to Add/Remove/associate devices
Notice: Including a node ID allocated by Z-Wave
"Inclusion". Excluding a node ID allocated by Z-Wave
"Remove" or "Exclusion".
TM
logo can also be used
Function
Add
(Inclusion)
TM
network with other Z-
1
TM
certified devices from other manufacturers and/or other applications. All non-
TM
500 series chip, when your Z-Wave
TM
500 series devices. The network system will have the
TM
Network
Description
1.
Have Z-Wave
TM
Controller entered inclusion mode.
2. Pressing tamper key three times within 2 seconds to enter the
inclusion mode.
TM
network system
TM
Controller means "Add" or
TM
Controller means

Advertisement

loading

Summary of Contents for Philio PAT05

  • Page 1 There are one tamper keys in the device, in the back side. Can be add, remove, reset or association from Z-WaveTM network. The PAT05 multi-sensor is a device that allows you to check the air quality in your home. The PAT05 Multi-sensor is easy to use and very convenient for your home. Just The table below lists an operation summary of basic Z-Wave functions.
  • Page 2 1. time. Or If your controller requires to have the PAT05 send a 'node information frame' or NIF for associations, then Tamper Report:...
  • Page 3 Event: Tampering. Product covering removed (0x03) Notice: * All of the configuration, the data size is 1. * The configuration mark with star(*), means after the remove the setting still keep, don't reset to factory default. Unless the user execute the “RESET” procedure. * Timing Report: * The reserve bit or not supported bit is allowed any value, but no effect.
  • Page 4 Name Def. Valid Description Name Def. Valid Description When there is a set value, it means that it will exceed or fall below the report. eCO2 difference return: TVOC difference return: The Unit is 100ppm. The Unit is 100ppb. eCO2 Threshold TVOC 1 ~ 100 0 means turn off eCO2 detected function.
  • Page 5 Name Def. Valid Description Command Class Version Required Security Class The interval time for auto report the eCO2. None Z-Wave Plus Info ECO2 Auto 1 ~ 127 The default value is 1. The tick time can Report Time Highest granted Security Class Version setting by the configuration No.16.
  • Page 6 They can take this product for environmental safe recycling. Rated Voltage DC5V from USB Range Minimum 40M in door and 100M in outdoor line of Philio Technology Corporation sight Operating Temperature -10°C ~ 40°C (85% humidity) 8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257, Taiwan(R.O.C)
  • Page 7 interference to radio communications. However, there is no guarantee can leak into the groundwater and get into the food chain, damaging that interference will not occur in a particular installation. If this your health and well-being. equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and When replacing old appliances with new once, the retailer is legally on, the user is encouraged to try to correct the interference by one of...