Power Up Procedure; Over The Air (Ota) Firmware Update - Philio PAT02-A-NS Manual

Flood multisensor
Table of Contents

Advertisement

It could be changed by setting the configuration NO. 10.
Low battery report: When the battery level is too low, every 30
minutes will report once.
Temperature report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 13.
Humidity report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 14.
Flood state report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 15.
Notice: The configuration NO. 10, 13, 14 and 15 could be setting to
zero to disable the auto report. And the configuration NO. 20 could
change the tick interval, the default value is 30, if setting to 1, that
means the minimum auto report interval will be one minute. And please
notice if setting this value to zero, that means disable all of the timing
report except the low battery detection.

Power Up Procedure

* Battery Power Check
When the device power up, the device will detect the power level of the
battery immediately. If the power level is too low, the LED will continue
flash about 5 seconds. Please change another new battery.
* NWI
When the device power on, the device will check is it already adding to
the network? If doesn't, it will auto start the NWI mode. The LED will
flash in every second and continue 30 seconds. Until timeout or the
device successful to inclusion by controller. The use can presses the
tamper key 3 times to abort the NWI mode.
PS: If the device already adding to the network, the device will
broadcast a node information once.
* Wake
When the device power on, the device will wake about 20 seconds. In
this duration, the controller can communicate with the device. Normally
the device is always sleeping to save the battery energy.

Over The Air (OTA) Firmware Update

The device support the Z-Wave firmware update via OTA.
Let the controller into the firmware update mode, and then press the
tamper key once to start the update.
After finish the firmware download, the LED will start flash in every 0.5
second. At that time, please don't remove the battery , otherwise it
will cause the firmware broken, and the device will no function.
After the LED stop flash, it is recommended that the user power up the
device. Caution: After remove the battery, please wait about 30
seconds, and then re-install the battery.