* Illumination Report:
When the door/window state changed, the device will unsolicited to
send the "Sensor Multilevel Report" to the nodes in the group 1.
Sensor Type: Luminance (0x03)
Note: To disable this functionality by setting the configuration setting
N0.5, the bit4 of the value to 1.
* Timing Report:
Beside the event triggered could report message, the device also
support the timing unsolicited report of the status.
Battery level report: Every 6 hours report once in default.
It could be changed by configuration setting NO. 10.
Low battery report: When the battery level is too low, every 30
minutes will report once.
Door/window state report: Every 6 hours report once in default.
It could be changed by configuration setting NO. 11.
Illumination level report: Every 6 hours report once in default.
It could be changed by configuration setting NO. 12.
Temperature report: Every 6 hours report once in default.
It could be changed by configuration setting NO. 13.

Power Up Procedure

* Battery Power Check
When the power up, the device will detect the power level of the
battery immediately. If the power level is too low, the LED will continue
flash about 5 seconds. Please change another new battery.
* NWI
When the power on, the device will check is it already adding to the
network? If doesn't, it will auto start the NWI mode. The LED will flash
in every second and continue 30 seconds. Until timeout or the device
successful to inclusion by controller.
* Wake
When the power on, the device will wake about 20 seconds. In this
duration, the controller can communicate with the device. Normally the
device is always sleeping to save the battery energy.

Operation Mode

There are two operation mode, "Test Mode" and "Normal Mode", the
"Test Mode" is for the user test the sensor function when installation.
When the event triggered, normally the LED won't indicated, unless the
battery is in the low level, the LED will flash once. And in the "Test
Mode" the LED also will light ON one second.
When the event triggered, the device will report the messages to the
nodes in the group 1. The messages also include the temperature and
the illumination level. The user can switch the report by configuration
setting NO. 5. When the event triggered, if the environment luminance
is less than the setting of the configuration setting NO. 4, the device
will emit the signal to turn ON the lighting equipment, those nodes in
the group 2. If the event is door/window close, it will delay about 5
seconds and emit the signal to turn OFF the lighting equipment.
Notice: When the tamper key of the back side is in the released state,
the device always in the "Test Mode".