Connecting to a G9SB-301-D

•Thin (22.5mm thick)
Emitter
F39-JC A-L
+DC24V
E1
0V
A1
A2
T21
T11
TH
SA
G9SB-301-D
Unblocked
Blocked
External test switch
(S1)
Interlock reset switch
(S2)
Emergency stop switch
(S3)
Safety output1, 2
K1,K2 N.O. contact
KM1,KM2 N.O. contact
K1,K2 N.C. contact
KM1,KM2 N.C. contact
PLC input 1(*)
PLC input 2
PLC output
* Output operation mode of auxiliary output 1 is "safety output information/reverse enabled" (initial setting)
Use G9SB-301-B for 3a+1b contact auto reset type.
Use G9SB-200-D for 2a contact manual reset type, or G9SB-200-B for 2a contact auto reset type. For details, see the
catalogs.
Receiver
F39-JC A-D
Communication
line (+) (Grey)
Communication
line (-) (Pink)
12
22
21
KM1
KM2
13
23
33
T12
T22
T31
T32
K1
K2
K1
K1
K2
a
Control
K2
Circuit
K1
a K2
14 24 34 42
KM1
KM2
*1 The G9SB-200-D (17.5 mm thick), with no 33-34 and 41-42, is also available.
*2 If an emergency stop switch is not used, connect safety output 1 to T12
terminal and safety output 2 to T22 directly.
S1
S2
S3
S4
KM1, KM2 :Magnetic contactor
KM3
M
E1
PLC
Input/Output Circuit and Applications
- F3SJ settings
- Auto reset mode
- Does not use external device monitoring function
- G9SB-301-D settings
- Manual reset mode
- Using feedback loop
PLC
IN1 IN2
OUT
KM3
*2
KM1
KM2
S3
*1
*1
M
41
*1
*1
:External test switch (connect to 0V if a switch is not required)
:Interlock reset switch
: Emergency stop switch (forcibly-opening contact)
(A165E, A22E)
:Lockout reset switch (connect to 24V if a switch is not required)
:Solid state contactor (G3J)
:3-phase motor
:24VDC power supply (S82K)
:Programmable controller
(Used for monitoring -- not related to safety system)
E
F3SJ-A
177
User's Manual