What can be done by the setting tool
Internal Indicator While Writing/Monitoring with the Setting
Tool
When using the setting tool to write settings to the F3SJ or while monitoring the incident light level
indicator, the [BLANKING (TEST)] indicator and an indicator on receiver's power connector side (see
below) blink.
When accessing at the administrator level, the indication lamps blink twice per second, and when
accessing at user level, they blink once per second.
For details about administrator level and user level, see p.65
F3SJ-A
64
User's Manual
While writing/monitoring with setting tool (Safety output is OFF)
Emitter
Receiver
POWER
INTLK
EDM
B LA N KIN G
(TEST)
Administrator level: Blinks twice
User level: Blinks once
OFF
ON
OFF