Omron Sti F3SJ-A Series User Manual page 207

Safety light curtain
Hide thumbs Also See for Sti F3SJ-A Series:
Table of Contents

Advertisement

ON
Blink
Emitter
Receiver
Error code
10, 11
C
C
B
B
A
A
19, *2
C
C
B
B
A
A
20
C
C
B
B
A
A
30, 31, 32,
C
C
37, 39
B
B
A
A
OFF
Error Description
Mutual
Disturbance light is received.
interference error
The receiver is receiving light
emitted from another photoelectric
switch or F3SJ.
Power supply
Power supply voltage is outside
capacity error
the rated range.
Voltage fluctuation due to
insufficient power supply capacity.
Instantaneous break or
instantaneous stop due to power
sharing with other devices.
Blanking
A fixed blanking beam other than
monitoring error
allowable beams received light.
Number of interrupted beams is
less than (number of floating
blanking beams - number of
allowable beams).
Communication
The communication line or other
error
wiring is broken or short-circuited.
Communication error due to
noise.
If the wiring is extended without
using the exclusive cord (F39-
JC
), no cord with the same
performance or more than the
exclusive cord is used.
Cause
Block the disturbance light.
p.120
See Chapter 4 "Mutual
Interference Prevention".
p.119
Connect to a 24VDC± 20% power
supply voltage.
Replace the power supply with
one that has a larger capacity.
Do not share the power supply
with other devices, and connect to
a power supply that is dedicated
to devices for electrical-detection
protective functions, such as the
F3SJ, safety controller, muting
sensor, etc.
Adjust a position of the device so
that a fixed blanking beam other
than allowable beam should not
receiver light. Or, configure fixed
blanking setting again.
p.66
Set number of floating blanking
beams and number of allowable
beams based on a size of
interrupting object.
p.70
Check the wiring and cables.
Check the noise level in the
environment around the
communication line. The inductive
noise tends to be induced
especially if the signal line and the
power line are arranged in
parallel. Be sure to lay the power
line away from the signal line.
Use a cord (twisted-pair cable)
with the same performance or
more than the exclusive cord
(F39-JC
the shield to the 0V line.
Appendix
Solution
). Otherwise connect
F3SJ-A
187
User's Manual
E

Advertisement

Table of Contents
loading

Table of Contents