Wiring When External Device Monitoring Function Is Not Required
1.Disabling external device monitoring function by the setting tool
Or
2.The external device monitoring function is disabled by connecting auxiliary output 1 and external
device monitoring input as shown below, when auxiliary output 1 settings have not been changed
(output operation mode is "safety output information" and reverse output mode is "enabled").
(Grey) Communication line (+)
(Pink) Communication line (-)
Ref.: Minimum Wiring Required to Check the Operation of the F3SJ When Using the
Muting Function
(Wiring that does not use the external device monitoring function)
M1 *1 *2
B1
A1
*1
* 1
3
*
3
*
A1
: Contact by muting sensor A1
B1
: Contact by muting sensor B1
M1
: Muting lamp
*1 When the muting function's operation check is not performed, it can work if this is open.
*2 Connect either the emitter or receiver to the muting lamp.
3 *
Two-wire type sensor cannot be used.
K1, K2
K3
*1 F3SJ can operate even if K3 is not connected.
K1
K2
K3
*1
(Grey) Communication line (+)
(Pink) Communication line (-)
System Configuration and Functions
: Relay or other device that controls
hazardous parts of the machine
: Load or PLC, etc. (for monitoring)
If K3 is not required, connect auxiliary output 1
to external device monitoring input only.
+24V D C
Power
supply
0V
+24V DC
Power
supply
0V
E
F3SJ-A
41