System Configuration and Functions
Use the PC tool for F3SJ to change following values:
T1min: Muting input time limit value (minimum)
T1max: Muting input time limit value (maximum)
Muting function p.91
To enable the muting function, D2, D3, and d2 must satisfy formulas (3), (4), and (5), respectively.
This distance must prevent the muting function from being enabled by a person passing through the
muting sensors. Also, install the F3SJ and muting sensors so that a workpiece passes through all
muting sensors before the next workpiece arrives at the first muting sensor.
Workpiece
Wiring Diagrams
A1
Two-wire type muting sensor cannot be used.
*
F3SJ-A
48
User's Manual
Workpiece
Moving direction
B1
A2
A1, B1, A2, B2 :
Regressive reflection
photoelectric switch
- PNP Output
- ON when Interrupted
B2
F3SJ
Workpiece
Workpiece
Moving direction
A1
A2
B1
B2
A1, A2, B1, B2:
N.O contact type switch
+24V DC
Power
supply