PJLink protocol

The network function of the projector supports PJLink class 1, and the PJLink protocol can be used to perform projector setting
and projector status query operations from a computer.
Control commands
The following table lists the PJLink protocol commands that can be used to control the projector.
f x characters in tables are non-specific characters.
Command
Control details
POWR
Power supply control
Power supply status
POWR ?
query
INPT
Input selection
INPT ?
Input selection query
AVMT
AV MUTE control
AVMT ?
AV MUTE status query
ERST ?
Error status query
Lamp status query
LAMP ?
Input selection list
INST ?
query
NAME ?
Projector name query
Manufacturer name
INF1 ?
query
INF2 ?
Model name query
INF0 ?
Other information query ×××××
CLSS ?
Class information query 1
PJLink security authorization
The password used for PJLink is the same as that of the password set for web control.
When using the projector without security authentication, do not set a password for web control.
f For specifications related to PJLink, refer to the website of Japan Business Machine and Information System Industries
Association.
URL http://pjlink.jbmia.or.jp/english/
Chapter 6 Appendix - Technical Information
Parameter / return string
0
1
0
1
2
3
11
12
21
31
32
30
31
××××××
××××××
11 12 21 31 32
×××××
Panasonic
VZ570
VW530
VX600
Remark
Standby
Power on
Standby
Power on
Cool-down in progress
Warm-up in progress
RGB 1
RGB 2
VIDEO
HDMI1
HDMI2
AV MUTE mode off
AV MUTE mode on
Indicates fan errors,
1st byte
range 0 – 2
Indicates lamp errors,
2nd byte
range 0 – 2
Indicates temperature
3rd byte
errors, range 0 – 2
4th byte Fixed at 0
Indicates filter errors,
5th byte
range 0 – 2
Indicates other errors,
6th byte
range 0 – 2
1st digits (1 – 5 digits) : Lamp cumulative operating time
2nd digit : 0 = Lamp off, 1 = Lamp on
Returns the name set in [NAME CHANGE] of
[NETWORK].
Returns manufacturer name.
Returns model name.
Returns information such as version number.
Returns class for PJLink.
f 0 = No error
known
f 1 = Warning
f 2 = Error
ENGLISH - 105