Indicator and projector state

Check the indicator to know about the state of projector.
Indicator
POWER
WARNING
(Green/Red/
(Red)
Yellow)
Green
Flash green
Appendix
The projector is in Off status (without AC power supply).
The projector is in standby status. Press Standby button to turn it on.
The projector is in normal status.
It is ready for standby or the lamp is cooling. You may power on the projector
only after the lamp is fully cooled and the POWER light indicator stops flashing.
The projector is in Ready mode.
The projector cannot power on, as its internal temperature is too high. You
may power it on after it is fully cooled, temperature backs to normal, and the
POWER light indicator turns red.
The projector detects lamp abnormality and switches into standby mode.
The projector detects the temperature abnormality and switches into standby
mode.
The projector detects power abnormality.
The projector detects fan abnormality.
The projector detects IRIS abnormality.
The projector detects its usage time ≥ the life of the projector -300H when the
projector usage time <1.1 times the life of the projector.
The projector detects its usage time ≥ 1.1times the life of the projector.
Red
Flash red
State of projector
Yellow
Flash Yellow
Off