Removing a 2.5-inch HDD/SSD module
Figure 45: Removing a 2.5-inch HDD/SSD module
▶ Pinch the green release button and open the locking lever (1).
▶ Pull the HDD/SSD module out a few centimeters (2).
▶ Wait about 30 seconds to allow the HDD to spin down.
This is not necessary when removing an SSD.
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
▶ Pull the HDD/SSD module completely out of its bay.
Installing a 2.5-inch HDD/SSD dummy module
CAUTION
If the removed HDD/SSD module is not replaced immediately,
always replace a dummy module into the unused HDD/SSD bay to
comply with applicable EMC regulations and satisfy cooling
requirements.
GX2570 M6
Hard disk drive (HDD) / solid state disk (SSD)
Upgrade and Maintenance Manual