Installing The Files After Installing Netware 4.X Or 5.0 - IBM Netfinity ServeRAID-3H Installation And User Manual

Hide thumbs Also See for Netfinity ServeRAID-3H:
Table of Contents

Advertisement

7. Click IPSRAID.HAM from the list of device drivers that appears in the window; then, press Enter.
Note: The IPSRAID.HAM and support files will be copied to the system volume.
8. Click OK to overwrite the existing files.
9. Follow the instructions in the NetWare manual to complete the installation.

Installing the files after installing NetWare 4.x or 5.0

Note: If the device driver is already installed and the operating system is installed on the ServeRAID
controller, do the following before starting this procedure:
1. Type:
Unload IPSRAID
2. Press Enter; then, go to step 1 in the following instructions.
To install the files after installing NetWare 4.x or 5.0, do the following:
1. From the system console, start the NetWare installation utility program by typing:
load install
2. Press Enter.
3. Insert the IBM ServeRAID Device Driver Diskette into the diskette drive or insert the IBM ServeRAID
Support CD into the CD-ROM drive.
4. Click Driver options from the Installation Options list.
5. Click Configure disk and storage from the Driver Options pop-up window.
6. Select Select an additional driver from the Additional Drivers Actions pop-up window.
7. When the next screen appears, press the Ins key to install an unlisted driver.
8. When the next screen appears, press the F3 key to specify a different path.
9. In the Specify a directory path field:
For NetWare 4.x: If you are installing from diskette, type:
a:\netware4
where a is the diskette drive letter.
For NetWare 4.x: If you are installing from CD-ROM, type:
d:\programs\netware\driver\netware4
where d is the CD-ROM drive letter.
For NetWare 5.0: If you are installing from diskette, type:
a:\netware5
where a is the diskette drive letter.
For NetWare 5.0: If you are installing from CD-ROM, type:
d:\programs\netware\driver\netware5
where d is the CD-ROM drive letter.
10. When prompted to select a device driver to install, select IPSRAID.HAM.
11. Select Yes when prompted to copy the IPSRAID.HAM driver.
12. When the prompt appears to specify the server boot path, type:
c:\nwserver
52
IBM ServeRAID-3H, ServeRAID-3HB, and ServeRAID-3L, Controllers